Search icon

GENESIS CONSTRUCTION SOLUTIONS, INC - Florida Company Profile

Company Details

Entity Name: GENESIS CONSTRUCTION SOLUTIONS, INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GENESIS CONSTRUCTION SOLUTIONS, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 24 Sep 2013 (12 years ago)
Date of dissolution: 25 Sep 2015 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (10 years ago)
Document Number: P13000078784
FEI/EIN Number 46-3731309

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3889 MELALEUCA LN, LAKE WORTH, FL, 33461
Mail Address: 3889 MELALEUCA LN, LAKE WORTH, FL, 33461
ZIP code: 33461
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RAMIREZ SALVADOR Director 3889 MELALEUCA LN, LAKE WORTH, FL, 33461
RAMIREZ SALVADOR President 3889 MELALEUCA LN, LAKE WORTH, FL, 33461
RAMIREZ SALVADOR Secretary 3889 MELALEUCA LN, LAKE WORTH, FL, 33461
RAMIREZ SALVADOR Treasurer 3889 MELALEUCA LN, LAKE WORTH, FL, 33461
RAMIREZ SALVADOR Agent 3889 MELALEUCA LN, LAKE WORTH, FL, 33461

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G13000094994 MASONRY SOLUTIONS EXPIRED 2013-09-25 2018-12-31 - 3889 MELALEUCA LN, LAKE WORTH, FL, 33461

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Documents

Name Date
ANNUAL REPORT 2014-05-01
Domestic Profit 2013-09-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339668576 0418800 2014-04-09 330 N. FEDERAL HIGHWAY, BOCA RATON, FL, 33432
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-04-09
Emphasis L: FALL, P: FALL
Case Closed 2019-03-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about 09 April, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on a scaffold that was not fully planked.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a. On or about 09 April, 2014, at the above addressed job site, employees were exposed to the hazard of falling while working on a scaffold that was supported by base plates which were resting on pieces of wood that were not flush and level with the ground.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Cross braces shall not be used as a means of access: a. On or about 09 April, 2014, at the above addressed job site; employees were exposed to the hazard of falling while using the lowest point of a scaffold platform, which was over two (2) feet from the ground, to gain access to the working level of the scaffold.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 E07
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(7): Steps and rungs of ladder and stairway type access shall line up vertically with each other between rest platforms: a. On or about 09 April, 2014, at the above addressed job site; employees were exposed to the hazard of falling while climbing the sides of scaffold to access the upper level of a scaffold with steps and rungs of the scaffold frame which were not vertically aligned with each other.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 E09 III
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(9)(iii): When erecting or dismantling tubular welded frame scaffolds, (end) frames, with horizontal members that are parallel, level and are not more than 22 inches apart vertically may be used as climbing devices for access, provided they are erected in a manner that creates a usable ladder and provides good hand hold and foot space: a. On or about 09 April, 2014, at the above addressed job site; employees were exposed to the hazard of falling while using the sides of a scaffold as a ladder where the rungs or steps on the scaffold had planking on the climbing surface near the top of the scaffold.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a. On or about 09 April, 2014, at the above addressed job site; employees were exposed to the hazard of falling while working from a scaffold that was not erected properly by a competent person.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about 09 April, 2014, at the above addressed job site; employees were exposed to the hazard of falling while working from a scaffold without any method of fall protection.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-04-23
Abatement Due Date 2014-05-05
Current Penalty 2450.0
Initial Penalty 4900.0
Final Order 2014-04-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. On or about 09 April, 2014, at the above addressed job site; employees were exposed to the hazard of falling while working on a scaffold without being trained on recognizing the hazards of working on a scaffold including how to properly erect, inspect, and use a scaffold.