Entity Name: | J ACEVEDO SERVICES INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
J ACEVEDO SERVICES INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 26 Aug 2013 (12 years ago) |
Date of dissolution: | 26 Sep 2014 (11 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 26 Sep 2014 (11 years ago) |
Document Number: | P13000071661 |
Address: | 5330 NW 36TH TERRACE, FORT LAUDERDALE, FL, 33309 |
Mail Address: | 5330 NW 36TH TERRACE, FORT LAUDERDALE, FL, 33309 |
ZIP code: | 33309 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ACEVEDO JOSE E | Director | 5330 NW 36TH TERRACE, FORT LAUDERDALE, FL, 33309 |
ACEVEDO JOSE E | Agent | 5330 NW 36TH TERRACE, FORT LAUDERDALE, FL, 33309 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2014-09-26 | - | - |
Name | Date |
---|---|
Domestic Profit | 2013-08-26 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339763468 | 0420600 | 2014-05-06 | 12611 SOUTH CLEVELAND AVENUE, FORT MYERS, FL, 33902 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2014-06-06 |
Abatement Due Date | 2014-06-18 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-07-28 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) For employees working at 12611 South Cleveland Avenue in Fort Myers, as observed on or about 6 May, 2014. Employees were installing stucco while standing on a 5:12 pitch roof of the building. Employees were working at an approximate height of 12 feet above the ground and the employees were not protected from falling. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 C02 |
Issuance Date | 2014-06-06 |
Abatement Due Date | 2014-06-18 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-07-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) For employees working at 12611 South Cleveland Avenue in Fort Myers, as observed on or about 6 May, 2014. Employees were installing stucco on the upper working surface of the building and stepping onto a supported scaffold that did not have base plates installed exposing employees approximately 12 feet above the ground to scaffolding collapse. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260451 F07 |
Issuance Date | 2014-06-06 |
Abatement Due Date | 2014-06-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-07-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) For employees working at 12611 South Cleveland Avenue in Fort Myers, as observed on or about 6 May, 2014. Employees installed a tubular frame scaffolding to hoist material to the upper working surface that was not erected or inspected by a competent person qualified in scaffolding erection. Tubular frame scaffolding was missing base plates and did not have fall protection installed on all sides to exposing employees to a fall hazard of approximately 12 feet. |