Search icon

VOLMAR CONSTRUCTION SERVICES INC - Florida Company Profile

Company Details

Entity Name: VOLMAR CONSTRUCTION SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

VOLMAR CONSTRUCTION SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 20 Aug 2013 (12 years ago)
Date of dissolution: 26 Sep 2014 (11 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 26 Sep 2014 (11 years ago)
Document Number: P13000069270
Address: 4583 BIEMHAS ROAD, 3, WEST PALM BEACH, FL, 33417
Mail Address: 4583 BIEMHAS ROAD, 3, WEST PALM BEACH, FL, 33417
ZIP code: 33417
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
VOLMAR PABLO M President 4583 BIEHMAS RD #3, WEST PALM BEACH, FL, 33417
MATOS VOLMAR P Agent 4583 BIEHMAS ROAD, WEST PALM BEACH, FL, 33417

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 - -

Documents

Name Date
Domestic Profit 2013-08-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339453680 0418800 2013-10-30 2100 E. ATLANTIC BOULEVARD, POMPANO BEACH, FL, 33062
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-10-30
Emphasis L: FALL, P: FALL
Case Closed 2019-03-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-12-04
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-02-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On October 30, 2013, at the above addressed site, an employee was exposed to a struck by hazard when using a circular saw and pneumatic nail gun while not wearing eye protection equipment.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-12-04
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-02-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On October 30, 2013, at the above addressed site, an employee was exposed to a fall hazard performing carpentry work on a walking/working surface approximately 10 feet above a lower level while not being protected from falling to that lower level.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2013-12-04
Abatement Due Date 2013-12-23
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-02-21
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On October 30, 2013, at the above addressed site, employees performing carpentry work exposed to potential falls were not provided with a training program that would enable them to recognize the hazards of falling. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-12-04
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-02-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On October 30, 2013, at the above addressed site, an employee performing carpentry work was exposed to a fall hazard while using an aluminum extension ladder that was not extended at least 3 feet above the upper landing surface to which he was gaining access to.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B08
Issuance Date 2013-12-04
Current Penalty 5000.0
Initial Penalty 5000.0
Final Order 2014-02-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: On October 30, 2013, at the above addressed site, employees performing carpentry work were exposed to a fall hazard while using an aluminum extension ladder set up in an active construction site that was not secured to prevent accidental displacement.