Search icon

ACCESO CONSTRUCTION INC

Company Details

Entity Name: ACCESO CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 07 Aug 2013 (12 years ago)
Date of dissolution: 25 Sep 2015 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (9 years ago)
Document Number: P13000066082
FEI/EIN Number 46-3400701
Address: 435 WESTWIND DR, DAVENPORT, FL 33896
Mail Address: 435 WESTWIND DR, DAVENPORT, FL 33896
ZIP code: 33896
County: Polk
Place of Formation: FLORIDA

Agent

Name Role Address
INAMAGUA, YESENIA Agent 435 WESTWIND DR, DAVENPORT, FL 33896

President

Name Role Address
INAMAGUA, YESENIA President 435 WESTWIND DR, DAVENPORT, FL 33896

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 No data No data
AMENDMENT 2013-08-30 No data No data

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J15000774030 TERMINATED 1000000687124 POLK 2015-07-13 2025-07-15 $ 1,449.33 STATE OF FLORIDA, DEPARTMENT OF REVENUE, LAKELAND SERVICE CENTER, 115 S MISSOURI AVE STE 202, LAKELAND FL338154644
J15000289377 LAPSED 14-268-D1 LEON 2014-10-03 2020-03-04 $329,273.02 DFS DIVISION OF WORKERS COMPENSATION, 200 EAST GAINES STREET, TALLAHASSEE, FL 32399-4228

Documents

Name Date
ANNUAL REPORT 2014-01-21
Amendment 2013-08-30
Domestic Profit 2013-08-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339873994 0420600 2014-07-30 IRIS SPRING DR., RIVERVIEW, FL, 33569
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-07-30
Emphasis L: FALL, P: FALL
Case Closed 2016-11-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-08-04
Current Penalty 2160.0
Initial Penalty 2160.0
Final Order 2014-09-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) At the site - employees were not provided a means of fall protection, while decking a 6/12 pitch residential roof exposing them to a 11 foot fall, on or about 7/30/2014.
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2014-08-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) At the site - employees working on the ground were not provided hard hats, exposing them to a struck-by injury hazard as debris was thrown from the roof, on or about, 7/30/2014.
339760159 0420600 2014-05-05 TRINITY LAKE APARTMENTS 1920 SPADE FISH BLVD., NEW PORT RICHEY, FL, 34655
Inspection Type Planned
Scope Partial
Safety/Health Safety
Emphasis L: FALL, P: FALL
Case Closed 2017-11-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-06-20
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-09-05
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Instance 1) Trinity Lake Apartments: an employee in the process of balcony work on the 2nd story balcony was exposed to a 10" 7 and 7/8th inch fall hazard, in that, fall protection equipment was not installed or utilized. Instance 2) Trinity Lake Apartments: an employee in the process of balcony work on the 3rd floor balcony was exposed to a 21" 3 and 3/4 inch fall hazard, in that, fall protection equipment was not installed or utilized.

Date of last update: 21 Feb 2025

Sources: Florida Department of State