Search icon

GIZMO CONCRETE INC - Florida Company Profile

Company Details

Entity Name: GIZMO CONCRETE INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

GIZMO CONCRETE INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 15 Jul 2013 (12 years ago)
Date of dissolution: 09 Jun 2016 (9 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 09 Jun 2016 (9 years ago)
Document Number: P13000059228
FEI/EIN Number 46-3189347

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1406 SUWANEE DR, WEST PALM BEACH, FL 33409
Mail Address: 1406 SUWANEE DR, WEST PALM BEACH, FL 33409
ZIP code: 33409
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MEDRANO, CORENE Agent 1406 SUWANEE DR, WEST PALM BEACH, FL 33409
MEDRANO, CORENE President 1406 SUWANEE DR, WEST PALM BEACH, FL 33409

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2016-06-09 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J18000076125 ACTIVE 1000000771925 PALM BEACH 2018-02-07 2038-02-21 $ 85,201.45 STATE OF FLORIDA, DEPARTMENT OF REVENUE, OUT OF STATE COLLECTIONS UNIT, 1415 W US HIGHWAY 90 STE 115, LAKE CITY FL320556156

Documents

Name Date
VOLUNTARY DISSOLUTION 2016-06-09
ANNUAL REPORT 2015-04-29
ANNUAL REPORT 2014-02-19
Domestic Profit 2013-07-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339832446 0418800 2014-06-18 2701 MONTCLAIR BLVD., MIRAMAR, FL, 33025
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2014-06-18
Emphasis L: FALL, P: FALL
Case Closed 2014-10-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-09-02
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2014-09-19
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 06/18/2014, at the above addressed location, employees working from a scaffold did not have a ladder for access exposing them to a fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F14
Issuance Date 2014-09-02
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2014-09-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: On or about 06/18/2014, at the above addressed location, an employee was standing on a concrete block that was placed on the scaffold planking exposing him to a fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-09-02
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-09-19
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about 06/18/2014, at the above addressed location, employees working on a scaffold that was on the third level of a building did not have fall protection exposing them to a fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2014-09-02
Abatement Due Date 2014-09-12
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2014-09-19
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work: On or about 06/18/2014, at the above addressed location, employees had not been trained by a competent person in the assembly of a scaffold.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-09-02
Abatement Due Date 2014-09-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-19
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about 06/18/2014, at the above addressed location, the employer did not have a Hazard Communication Program for employees working with chemicals such as concrete and silica.