Search icon

EXCELLENCE MARINE, INC. - Florida Company Profile

Company Details

Entity Name: EXCELLENCE MARINE, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

EXCELLENCE MARINE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 18 Jun 2013 (12 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P13000052966
FEI/EIN Number 46-3100108

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2900 7TH AVENUE E., TAMPA, FL, 33605
Mail Address: 2900 7TH AVENUE E., TAMPA, FL, 33605
ZIP code: 33605
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RESCH BRADLEY J President 2900 7TH AVENUE E., TAMPA, FL, 33605
RESCH BRADLEY J Agent 2900 7TH AVENUE E., TAMPA, FL, 33605

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G15000041029 VELOCITY BOATWORKS EXPIRED 2015-04-24 2020-12-31 - 2900 E 7TH AVE, TAMPA, FL, 33605
G13000077904 VELOCITY POWERBOATS EXPIRED 2013-08-05 2018-12-31 - 2900 7TH AVENUE E, TAMPA, FL, 33605

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2025-07-01 2900 7TH AVENUE E., TAMPA, FL 33605 -
CHANGE OF MAILING ADDRESS 2025-07-01 2900 7TH AVENUE E., TAMPA, FL 33605 -
CHANGE OF PRINCIPAL ADDRESS 2024-07-01 2900 7TH AVENUE E., TAMPA, FL 33605 -
CHANGE OF MAILING ADDRESS 2024-07-01 2900 7TH AVENUE E., TAMPA, FL 33605 -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
ANNUAL REPORT 2018-01-31
ANNUAL REPORT 2017-02-14
ANNUAL REPORT 2016-03-21
ANNUAL REPORT 2015-01-19
ANNUAL REPORT 2014-01-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340151919 0420600 2014-12-22 1770 E LAKE MARY BLVD #4, SANFORD, FL, 32773
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2014-12-22
Emphasis L: EISAOF, L: EISAX
Case Closed 2015-04-07

Related Activity

Type Complaint
Activity Nr 927398
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100106 E06 II
Issuance Date 2015-03-09
Abatement Due Date 2015-04-02
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-04-06
Nr Instances 2
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees Fahrenheit (37.8 degrees Celsius), were dispensed into containers without the nozzle and container being electrically interconnected: a. Northeast chemical storage room - steel drum used to transfer flammable resin to containers with a pump was not grounded. Violation observed on or about 12/22/14. b. Northeast chemical storage room - steel drum used to transfer flammable acetone to containers with a pump was not grounded. Violation observed on or about 12/22/14.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100107 B10
Issuance Date 2015-03-09
Abatement Due Date 2015-04-02
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(10): Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit is located: a. Spray booth - employees were exposed to burn hazards, in that, the electrical illumination panels were damaged. Violation observed on or about 12/22/14.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100107 E02
Issuance Date 2015-03-09
Abatement Due Date 2015-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were exceeded for operations and ordinarily exceeded a supply for 1 day or one shift: a. Spray booth - flammable liquids such as, but not limited to cleaner, adhesion promoter and gel coat were permanently stored inside of the spray booth during spraying operations. Violation observed on or about 12/22/14.
Citation ID 01003
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2015-03-09
Abatement Due Date 2015-04-23
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 8
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. Manufacturing areas - the employer did not provide a written hazard communication program for employees exposed to products such as, but not limited to, gel coat, paint, primer, resin, acetone, thickening agent, fiberglass and activator. Violation observed on or about 12/22/14.
Citation ID 02001
Citaton Type Other
Standard Cited 19100107 B09
Issuance Date 2015-03-09
Abatement Due Date 2015-04-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a. Spray booth - materials such as, but not limited to shelving, wood pieces, and carts were stored adjacent to the exterior walls of the spray booth. Violation observed on or about 12/22/14.
Citation ID 02002
Citaton Type Other
Standard Cited 19100107 G02
Issuance Date 2015-03-09
Abatement Due Date 2015-04-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a. Spray booth - built-up soiled debris accumulated on top of the walls inside of the spray booth. Violation observed on or about 12/22/14.
Citation ID 02003
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2015-03-09
Abatement Due Date 2015-04-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. Spray booth - when respirators were required for spraying operations, the employer did not provide a written respiratory protection program. Violation observed on or about 12/22/14.
Citation ID 02004
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2015-03-09
Abatement Due Date 2015-04-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Spray booth - when respirators were required for spraying operations, the employer did not provide medical evaluations. Violation observed on or about 12/22/14.
Citation ID 02005
Citaton Type Other
Standard Cited 19100134 F01
Issuance Date 2015-03-09
Abatement Due Date 2015-04-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-04-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. Spray booth - during spraying operations where respirators were required, the employer did not provide fit testing. Violation observed on or about 12/22/14.