Entity Name: | DAVID KNIGHT STUCCO INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
DAVID KNIGHT STUCCO INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 23 May 2013 (12 years ago) |
Date of dissolution: | 27 Sep 2019 (6 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2019 (6 years ago) |
Document Number: | P13000045657 |
FEI/EIN Number |
46-2952179
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1410 VANDER AVE, PALM BAY, FL, 32909 |
Mail Address: | 1410 VANDER AVE, PALM BAY, FL, 32909 |
ZIP code: | 32909 |
County: | Brevard |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
KNIGHT DAVID JR | President | 1410 VANDER AVE, PALM BAY, FL, 32909 |
KNIGHT DAVID T | Vice President | 3240 IDEAL AVE NE, PALM BAY, FL, 32905 |
KNIGHT DAVID JR | Agent | 1410 VANDER AVE, PALM BAY, FL, 32909 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2018-04-26 |
ANNUAL REPORT | 2017-06-28 |
ANNUAL REPORT | 2016-04-30 |
ANNUAL REPORT | 2015-04-28 |
ANNUAL REPORT | 2014-05-01 |
Domestic Profit | 2013-05-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341723286 | 0418800 | 2016-08-24 | 11368 SW PATTERSON ST, PORT SAINT LUCIE, FL, 34986 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2016-09-06 |
Abatement Due Date | 2016-09-30 |
Current Penalty | 2138.0 |
Initial Penalty | 2138.0 |
Final Order | 2016-11-14 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about August 24, 2016, at the above addressed jobsite, two employees were performing stucco work while on the second level of a two tier tubular welded frame scaffold that was not fully planked at the level they were working at, exposing the employees to a fall hazard of approximately 12 feet. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 C02 |
Issuance Date | 2016-09-06 |
Abatement Due Date | 2016-09-30 |
Current Penalty | 2138.0 |
Initial Penalty | 2138.0 |
Final Order | 2016-11-14 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about August 24, 2016 employees were working from a scaffold that was missing base plates. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2016-09-06 |
Abatement Due Date | 2016-09-30 |
Current Penalty | 2138.0 |
Initial Penalty | 2138.0 |
Final Order | 2016-11-14 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about August 24, 2016, at the above addressed jobsite, two employees were performing stucco work while on the second level of a two tier tubular welded frame scaffold that did have guardrails all installed anywhere on the second level, exposing the employees to a fall hazard of approximately 12 feet. |