Search icon

UNIQUE CONSTRUCTION GROUP INC - Florida Company Profile

Company Details

Entity Name: UNIQUE CONSTRUCTION GROUP INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

UNIQUE CONSTRUCTION GROUP INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 07 Mar 2013 (12 years ago)
Date of dissolution: 23 Sep 2016 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (9 years ago)
Document Number: P13000021870
FEI/EIN Number 46-2248595

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 38533 NAOMI AVE, ZEPHYRHILLS, FL, 33542, US
Mail Address: 38533 NAOMI AVE, ZEPHYRHILLS, FL, 33542, US
ZIP code: 33542
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PULIDO ARNULFO President 38533 NAOMI AVE, ZEPHYRHILLS, FL, 33542
PULIDO ARNULFO Director 38533 NAOMI AVE, ZEPHYRHILLS, FL, 33542
PULIDO ARNULFO Agent 38533 NAOMI AVE, ZEPHYRHILLS, FL, 33542

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -
AMENDMENT 2013-04-12 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J16000027346 LAPSED 2015CC-001435 10TH JUDICIAL, POLK COUNTY 2015-08-03 2021-01-19 $7,462.63 RETAIL FIRST INSURANCE COMPANY, 2310 COMMERCE POINT DRIVE, LAKELAND, FL 33801

Documents

Name Date
ANNUAL REPORT 2015-01-21
ANNUAL REPORT 2014-06-11
Domestic Profit 2013-03-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340056175 0420600 2014-10-31 32727 COLDWATER CREEK LOOP, WESLEY CHAPEL, FL, 33545
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-10-31
Emphasis L: FALL, P: FALL
Case Closed 2017-10-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-11-07
Abatement Due Date 2014-11-14
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-12-11
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, an employee was exposed to a 9'- 4" fall hazard while walking on top of a concrete block wall and not using fall protection. This violation was observed on or about October 31, 2014.
339156465 0420600 2013-06-26 21547 SOUTHERN CHARMS DR., LAND O LAKES, FL, 34637
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-06-26
Emphasis L: FALL, P: FALL
Case Closed 2013-10-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2013-07-19
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2013-08-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 06-26-2013, on a residential house rooftop (7/12 slope) where the roof was being decked the use of fall protection was not enforced exposing an employee to a 10 foot fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2013-07-19
Abatement Due Date 2013-08-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about 06-26-2013 on the job site, the employer did not establish written records of training for the employees.

Date of last update: 01 Apr 2025

Sources: Florida Department of State