Search icon

JESSIE'S CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: JESSIE'S CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

JESSIE'S CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 28 Feb 2013 (12 years ago)
Date of dissolution: 26 Sep 2014 (11 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 26 Sep 2014 (11 years ago)
Document Number: P13000019478
Address: 1214 NOSLEDA ST, PLANT CITY, FL, 33563, US
Mail Address: 1214 NOSLEDA ST, PLANT CITY, FL, 33563, US
ZIP code: 33563
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MORENO JOSE President 1214 NOSLEDA ST, PLANT CITY, FL, 33563
MORENO JOSE Director 1214 NOSLEDA ST, PLANT CITY, FL, 33563
MORENO JOSE Agent 1214 NOSLEDA ST, PLANT CITY, FL, 33563

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 - -

Documents

Name Date
Domestic Profit 2013-02-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340529205 0420600 2015-04-09 13832 MOONSTONE CANYON DR, RIVERVIEW, FL, 33579
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-04-09
Emphasis P: FALL, L: FALL
Case Closed 2017-11-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-04-28
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2015-06-23
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. Along the exterior wall, the single tier fabricated frame scaffolding was not fully planked, exposing employees to a 5 foot fall hazard, on or about 04/09/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2015-04-28
Current Penalty 1700.0
Initial Penalty 1700.0
Final Order 2015-06-23
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement: a. Along the exterior wall, single tier fabricated frame scaffolding was not braced, exposing employees to a 5 foot fall hazard, on or about 04/09/2015.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E06 VI
Issuance Date 2015-04-28
Abatement Due Date 2015-05-15
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-06-23
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(6)(vi): Integral prefabricated scaffold access frames shall have a maximum spacing between rungs of 16 3/4 inches (43 cm): a. Along the exterior wall, single tier prefabricated frame scaffolding with rungs spaced 20 inches apart were used by employees as a ladder to gain access to the working level of the scaffolding, exposing the employees to 5 foot fall hazard, on or about 04/09/2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 D01 III
Issuance Date 2015-04-28
Abatement Due Date 2015-06-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-23
Nr Instances 1
Nr Exposed 9
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a. Near the rear exterior wall, the employer did not evaluate the respiratory hazards that come from cutting concrete blocks with a STIHL TS420 concrete saw, exposing employees to silica dust and possible respiratory illnesses, on or about 04/09/2015.
Citation ID 02002
Citaton Type Other
Standard Cited 19260102 A01
Issuance Date 2015-04-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-23
Nr Instances 2
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. Near the rear of the exterior wall, eye protection was not provided to the operators of a STIHL TS-420 CutQuik concrete saw, exposing employees to the hazard of struck-by, on or about 04/09/2015. b. Near the scaffolding, eye protection was not provided to the employees using hammers to split concrete blocks, exposing employees to the hazard of struck-by, on or about 04/09/2015.
Citation ID 02003
Citaton Type Other
Standard Cited 19260454 B02
Issuance Date 2015-04-28
Abatement Due Date 2015-05-15
Current Penalty 400.0
Initial Penalty 400.0
Final Order 2015-06-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b)(2): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question: a. Along the exterior wall, employees erected, disassembled, and worked from scaffolding without being trained on the hazards associated with scaffolding, exposing the employees to a 5 foot fall hazard, on or about 04/09/2015.

Date of last update: 03 Apr 2025