Entity Name: | C J G CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
C J G CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 04 Feb 2013 (12 years ago) |
Date of dissolution: | 09 Sep 2014 (11 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 09 Sep 2014 (11 years ago) |
Document Number: | P13000011410 |
Address: | 7005 DE AURRECOECHEA DRIVE, SOUTHPORT, FL, 32409 |
Mail Address: | P O BOX 8127, SOUTHPORT, FL, 32409 |
ZIP code: | 32409 |
County: | Bay |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
GARRISON CHRISTOPHER | President | P O BOX 8127, SOUTHPORT, FL, 32409 |
GARRISON CHRISTOPHER | Vice President | P O BOX 8127, SOUTHPORT, FL, 32409 |
GARRISON CHRISTOPHER J | Agent | 7005 DE AURRECOECHEA DRIVE, SOUTHPORT, FL, 32409 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2014-09-09 | - | - |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2014-09-09 |
Domestic Profit | 2013-02-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339097370 | 0419700 | 2013-05-30 | 499 BECKMAN ROAD, PANAMA CITY BEACH, FL, 32407 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2013-06-25 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-07-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. On or about May 30, 2013, on the 7:12 pitch roof, employees performing siding work were not protected from an 12 feet 6-inch fall hazard by the use of a fall protection system. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2013-06-25 |
Abatement Due Date | 2013-07-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-07-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about April 11, 2013, employees working from elevations were not trained about fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2013-06-25 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-07-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about May 30, 2013, employees on the roof, were using an 8-foot Werner stepladder that was folded together in order to gain access and egress from a parapet wall to the roof, exposing employees to a 6 feet fall hazard. |