Search icon

SOCIAL QUALITY CONSTRUCTION, INC - Florida Company Profile

Company Details

Entity Name: SOCIAL QUALITY CONSTRUCTION, INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

SOCIAL QUALITY CONSTRUCTION, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 17 Dec 2012 (12 years ago)
Date of dissolution: 27 Sep 2013 (12 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2013 (12 years ago)
Document Number: P12000102246
Address: 5520 TURIN STREET, ORLANDO, FL, 32807, US
Mail Address: 5520 TURIN STREET, ORLANDO, FL, 32807, US
ZIP code: 32807
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ZUNIGA MERAZ MARIA L President 5520 TURIN STREET, ORLANDO, FL, 32807
ZUNIGA MERAZ MARIA L Vice President 5520 TURIN STREET, ORLANDO, FL, 32807
ZUNIGA MERAZ MARIA L Treasurer 5520 TURIN STREET, ORLANDO, FL, 32807
AVILA BARNICA ELSA M Secretary 5520 TURIN STREET, ORLANDO, FL, 32807
AVILA BARNICA ELSA M Agent 5520 TURIN STREET, ORLANDO, FL, 32807

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -

Documents

Name Date
Domestic Profit 2012-12-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339484255 0419700 2013-11-14 32 CHARTER CIRCLE, PONTE VEDRA, FL, 32082
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-11-14
Emphasis P: FALL, L: FALL
Case Closed 2020-08-19

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-12-09
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 14, 2013, an employee was working in the trusses without the use of any fall protection systems, exposing himself to a 9 feet 9-inch fall hazard.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2013-12-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a. On or about November 14, 2013, the employer had not provided fall protection training to employees that were and might be exposed to fall hazards.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2013-12-09
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about November 14, 2013, an employee used the top and top step of the 6-foot stepladder for access to and from the trusses, exposing himself to a 6 feet fall hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B16
Issuance Date 2013-12-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a. On or about November 14, 2013, an employee used the damaged 6-foot stepladder for access to and from the trusses, exposing himself to a 6 feet fall hazard.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2013-12-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a. On or about November 14, 2013, the employer had not provided ladder safety training to the employees that used or might use ladders to recognize ladder hazards.
339485773 0419700 2013-11-12 12409 DEWHURST CIRCLE - LOT 69, JACKSONVILLE, FL, 32208
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-11-12
Emphasis L: FALL, P: FALL
Case Closed 2018-07-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-12-04
Abatement Due Date 2013-12-12
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about November 12, 2013, employees using nail guns were not wearing safety glasses, exposing themeselves to eye injuries. Abatement Certification and Documentation are required
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2013-12-04
Abatement Due Date 2013-12-12
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system: a. On or about November 12, 2013, roof, the employee installing lathe around the window on a 4:12 pitch roof was not wearing fall protection exposing himself to a 9.5 feet fall hazard. Abatement Certification and Documentation are required
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-12-04
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-01-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder: a. On or about November 12, 2013, employees were using a 16-foot extension ladder that was only extended about 18 inches above the landing and was not secured to prevent accidental movement, exposing themselves to a 9.5 feet fall hazard. Abatement Certification and Documentation are not required