Search icon

GLOBAL BOUNDARIES INC. - Florida Company Profile

Company Details

Entity Name: GLOBAL BOUNDARIES INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GLOBAL BOUNDARIES INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 11 Dec 2012 (12 years ago)
Date of dissolution: 27 Sep 2013 (12 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2013 (12 years ago)
Document Number: P12000100792
Address: 1234 COMMERCE BLVD, SARASOTA, FL, 34243, US
Mail Address: 1234 COMMERCE BLVD, SARASOTA, FL, 34243, US
ZIP code: 34243
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GENTLE LAURA Director 1234 COMMERCE BLVD, SARASOTA, FL, 34243
GENTLE RYAN Director 5315 8TH AVE DR W, BRADENTON, FL, 34209
GENTLE LAURA Agent 1234 COMMERCE BLVD, SARASOTA, FL, 34243

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -

Documents

Name Date
Domestic Profit 2012-12-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339483927 0420600 2013-11-14 1234 COMMERCE BLVD., SARASOTA, FL, 34243
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2013-11-14
Emphasis N: AMPUTATE
Case Closed 2017-11-01

Related Activity

Type Inspection
Activity Nr 913663
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19100305 G02 III
Issuance Date 2013-12-12
Abatement Due Date 2013-12-24
Current Penalty 800.0
Initial Penalty 800.0
Final Order 2014-02-03
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 11/14/2013, a) Two TIG welder power cables had their outer insulation damaged as they entered an electrical cabinet and the welder. This resulted in strain being placed on the inner conductors. b) Multiple power cords associated with the Eagle Bender had outer insulation damaged and torn away resulting in strain being placed on the inner conductors. Global Boundaires Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(2)(iii), which was contained in OSHA inspection number 913663, citation number 1, item number 5b and was affirmed as a final order on 09/19/2013, with respect to a workplace located at 1234 Commerce Blvd. South in Sarasota, FL 34243.
Citation ID 02001
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2014-02-26
Abatement Due Date 2014-04-02
Current Penalty 400.0
Initial Penalty 400.0
Final Order 2014-03-24
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer failed to certify to OSHA (the Agency) that the following item Citation 1 Item 1 was abated within 10 calendar days after the abatement date.
339136632 0420600 2013-06-25 1234 COMMERCE BLVD. S., SARASOTA, FL, 34243
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-06-25
Emphasis N: AMPUTATE
Case Closed 2017-11-01

Related Activity

Type Complaint
Activity Nr 825193
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2013-07-30
Abatement Due Date 2013-08-06
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, a metal chop saw was used to cut aluminum bars. The saw was missing its lower guard which had been broken off.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100217 B01
Issuance Date 2013-07-30
Abatement Due Date 2013-08-16
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(b)(1): Machine component(s) of mechanical power press(es) were not designed, secured, or covered to minimize hazards caused by breakage, or loosening and falling, or release of mechanical energy: a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, employees used a Benchmaster mechanical power/punch press with an unguarded flywheel, belt and pulley. Employees were exposed to hazardous energy from the unguarded flywheel and belt/pulley apparatus. In the past, the fly heel had fallen off the press due to a faulty attachment to the crankshaft.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100217 B04 I
Issuance Date 2013-07-30
Abatement Due Date 2013-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, employees used a Benchmaster mechanical power/punch press and the actuating foot pedal for the mechanical power press was not protected from being inadvertently stepped on or from having material dropped on it.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100217 C01 I
Issuance Date 2013-07-30
Abatement Due Date 2013-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, a benchmaster mechanical punch press was used to stamp/punch out metal pieces. There was no machine guarding of any kind to protect the operator from the point of operation.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100243 C01
Issuance Date 2013-07-30
Abatement Due Date 2013-08-07
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4): a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, employees were observed using a portable hand grinder with an abrasive wheel 4 inches or more in diameter that was missing its safety guard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100303 B07 I
Issuance Date 2013-07-30
Abatement Due Date 2013-08-07
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, two breaker slots were missing in a live 220V cabinet used to power a TIG welder. Employees using the breaker cabinet were exposed to potential contact with live parts.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2013-07-30
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, during operation, live wires that had been spliced were exposed on the 120/220V motor of a punch press. The wires were not housed by any electrical box but were out in the open where they could be contacted.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2013-07-30
Abatement Due Date 2013-08-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-20
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, a) flexible cords used to power a mechanical punch press had their insulation damaged/removed at their plugs resulting in strain being placed on the inner terminal conductors/screws. b) Two TIG welder power cables had their outer insulation damaged as they entered an electrical cabinet and the welder. This resulted in strain being placed on the inner conductors.
Citation ID 01005C
Citaton Type Serious
Standard Cited 19100334 A02 II
Issuance Date 2013-07-30
Abatement Due Date 2013-08-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-09-20
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) For the Global Boundaries establishment at 1234 Commerce Blvd. S, Sarasota, FL 34243, as observed on or about 06/25/2013, the outer jacket of an extension cord and power cord for a punch press recently used had worn away.

Date of last update: 01 Apr 2025