Search icon

K'ALOMA DESIGN GROUP INC - Florida Company Profile

Company Details

Entity Name: K'ALOMA DESIGN GROUP INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

K'ALOMA DESIGN GROUP INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 Nov 2012 (12 years ago)
Date of dissolution: 24 Sep 2021 (4 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 24 Sep 2021 (4 years ago)
Document Number: P12000096136
FEI/EIN Number 461428643

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2264 West 8th Court, Hialeah, FL, 33010, US
Mail Address: 2264 West 8th Court, Hialeah, FL, 33010, US
ZIP code: 33010
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ALOMA CARLOS President 2264 West 8th Court, Hialeah, FL, 33010
ALOMA CARLOS Director 2264 West 8th Court, Hialeah, FL, 33010
ALOMA CARLOS Agent 2264 West 8th Court, Hialeah, FL, 33010

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
REGISTERED AGENT ADDRESS CHANGED 2019-04-23 2264 West 8th Court, Hialeah, FL 33010 -
CHANGE OF PRINCIPAL ADDRESS 2019-04-23 2264 West 8th Court, Hialeah, FL 33010 -
CHANGE OF MAILING ADDRESS 2019-04-23 2264 West 8th Court, Hialeah, FL 33010 -
REGISTERED AGENT NAME CHANGED 2015-11-23 ALOMA, CARLOS -
REINSTATEMENT 2015-11-23 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -
REINSTATEMENT 2014-11-26 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 - -

Documents

Name Date
ANNUAL REPORT 2020-04-22
ANNUAL REPORT 2019-04-23
ANNUAL REPORT 2018-02-13
ANNUAL REPORT 2017-02-28
ANNUAL REPORT 2016-04-15
REINSTATEMENT 2015-11-23
REINSTATEMENT 2014-11-26
ANNUAL REPORT 2013-04-18
Domestic Profit 2012-11-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340496538 0418800 2015-03-23 3009 PINE TREE DR, MIAMI BEACH, FL, 33140
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-03-23
Emphasis L: FALL, P: FALL
Case Closed 2020-04-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of head injuries from overhead falling objects such as hand tools and metal materials while working below and adjacent to a scaffold system without the use of hardhats.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use: (a) On or about March 23, 2015, at the above addressed worksite, employees were exposed to injuries from flying metal debris and/or abrasive wheel fragments while operating a DeWalt angle grinder without its guard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260300 C
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(c): Employees using hand and power tools and exposed to the hazard of falling, flying, abrasive, or splashing objects, or exposed to harmful dusts, fumes, mists, vapors, or gases were not provided with the particular personal protective equipment necessary to protect them from the hazard: (a) On or about March 23, 2015, at the above addressed worksite, employees were exposed to eye injuries from flying metal debris and/or abrasive wheel fragments while operating an unguarded DeWalt angle grinder without appropriate eye protection.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-05-19
Current Penalty 680.0
Initial Penalty 1360.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls between 16 and 24 feet while working from the second and third tiers of a scaffold system that were not fully planked.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-05-19
Current Penalty 680.0
Initial Penalty 1360.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls between 8 and 24 feet while working from a scaffold with uprights bearing on inadequate foundation.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls between 8 and 24 feet while working from a scaffold which had an upright bearing on a concrete cinder block.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls between 8 and 24 feet while working from a scaffold that was not inspected by a competent person before the work shift.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 1360.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls between 8 and 24 feet while working from a scaffold that was missing guardrail systems.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19260451 H02 II
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falling objects of distances between 16 and 24 feet while working from and below a scaffold that was missing toeboards.
Citation ID 01008
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls between 8 and 24 feet while working from a scaffold prior to being provided with training for the hazards associated with the scaffold being used.
Citation ID 01009A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2015-05-19
Current Penalty 680.0
Initial Penalty 1360.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls while using an 8 foot step ladder leaning against a scaffold without using the spreader.
Citation ID 01009B
Citaton Type Serious
Standard Cited 19261053 B09
Issuance Date 2015-05-19
Abatement Due Date 2015-06-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to the hazards of falls while using an extension ladder that had landscaping rock piled around its base.
Citation ID 02001
Citaton Type Other
Standard Cited 19260403 B02
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using a 4-way gang box at the end of an extension cord to power their portable hand tools.
Citation ID 02002
Citaton Type Other
Standard Cited 19260404 B01 III C
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(iii)(C): Where an assured equipment grounding conductor program was being utilized, the employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected fofore each day's use for external defects, such as deformed or missing pins or insulation damage, and for indicationsof possible internal damage (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using an extension cord missing a ground pin to power a DeWalt portable right angle grinder.
Citation ID 02003
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2015-05-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-22
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a): On or about March 23, 2015, at the above addressed worksite, employees were exposed to electrical hazards while using an extension cord missing a strain relief on the 3 receptacle end to power a DeWalt portable right angle grinder.

Date of last update: 02 Apr 2025

Sources: Florida Department of State