Search icon

CRG 2013 SERVICES INC

Company Details

Entity Name: CRG 2013 SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 19 Nov 2012 (12 years ago)
Date of dissolution: 26 Sep 2014 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 26 Sep 2014 (10 years ago)
Document Number: P12000095900
FEI/EIN Number 46-1415054
Address: 1080 SHOAGLAND BLVD, #74, KISSIMMEE, FL 34741
Mail Address: 1080 SHOAGLAND BLVD, #74, KISSIMMEE, FL 34741
ZIP code: 34741
County: Osceola
Place of Formation: FLORIDA

Agent

Name Role Address
GONZALEZ, CHARLIE R Agent 1080 SHOAGLAND BLVD, #74, KISSIMMEE, FL 34741

President

Name Role Address
GONZALEZ, CHARLIE R President 1080 SHOGLAND BLVD #74, ORLANDO, FL 34741

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 No data No data

Documents

Name Date
ANNUAL REPORT 2013-04-03
Domestic Profit 2012-11-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339439259 0419700 2013-10-23 4733 PLANTATION OAK BLVD. LOT 180, ORANGE PARK, FL, 32065
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-10-24
Emphasis P: FALL, L: FALL
Case Closed 2018-09-12

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about October 23, 2013, the employee applying stucco on the first level of the scaffold system was underneath an employee on the next level of the scaffold system. The employees were not wearing hard hats, exposing themselves to head injuries. Abatement Certification and Documentation are not required
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 H02 II
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a. On or about October 23, 2013, toeboards were not erected along the edge of platforms, exposing the employee working below to head injuries.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about October 21, 2013, the employee mixing cement did not have on safety glasses, exposing himself to possible eye injuries. Abatement Certification and Documentation are not required
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-09
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about October 21, 2013, front and left side of the home, an employee apply stucco on the second level of the scaffold system that was not fully planked. The platform had two planks with an 8-inch gap, exposing the employee to a 13 feet fall hazard. b. On or about October 21, 2013, front and left side of the home, an employee applying stucco from the first level of the scaffold system that was not fully planked. The platform only had one plank, exposing the employee to a 7 feet 3-inch fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about October 23, 2013, the two buck high scaffold system erected in the sand on the left side and front of the home, did not have any base plates or mudsills.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-09
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a. On or about October 21, 2013, left side of the home, an employee accessed the second level of the scaffold system and applied stucco material by using the end rails of the scaffold. The scaffold system was not equipped with a ladder, exposing the employee to an 13 feet fall hazard. b. On or about October 21, 2013, the left side of the home, an employee access the first level of the scaffold system and applied stucco material by using the end rails of the scaffold. The scaffold system was not equipped with a ladder, exposing the employee to a 7 feet 3 inch fall hazard.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-11-22
Abatement Due Date 2013-12-27
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. On or about October 23, 2013, employees applying stucco on the front and left sides of the home were working on a scaffold system that was not erected under the supervison of a competent person.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2013-11-22
Abatement Due Date 2013-12-03
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a. On or about October 23, 2013, left side of the home, an employee applying stucco material on the second level of the scaffold system was exposed to a fall hazard of 13 feet because the ends of the platform were not enclosed by a guardrail system.
Citation ID 02001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2013-11-22
Abatement Due Date 2013-12-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about October 23, 2013, a written hazard communication program was not developed, implemented and maintained for employees who worked with hazardous chemicals such as but not limited to Titan stucco cement (irritant).
Citation ID 02001B
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2013-11-22
Abatement Due Date 2013-12-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a. On or about October 23, 2013, the employer did not have a material safety data sheet for the Titan stucco cement being mixed and applied to the exterior of the home.
Citation ID 02001C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2013-11-22
Abatement Due Date 2013-12-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-09
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about October 23, 2013, the employer did not provide training for employees working with but not limited to Titan stucco cement. Employees were mixing cement and applying cement to the exterior of the home.
339247652 0420600 2013-08-02 6801 SEA CORAL DRIVE, ORLANDO, FL, 32802
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-08-02
Emphasis L: FALL, P: FALL
Case Closed 2017-12-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 IV
Issuance Date 2013-10-22
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-12-23
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: (a) At the 6801 Sea Corral Avenue, location two employees working from an aerial lift where one of them was standing on the midrail of the guardrail system while working from the basket of the aerial lift as observed on or about August 2, 2013.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2013-10-22
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-12-23
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated. (a). At the 6801 Sea Corral Avenue, location two employees working from an aerial lift where one of them had no personal fall arrest or safety belt and lanyard to be connected to the basket or boom to protect from falls while working from the basket of the aerial lift as observed on or about August 2, 2013.

Date of last update: 22 Feb 2025

Sources: Florida Department of State