Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-11-09
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2022-06-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2022-03-02 |
Current Penalty |
2610.6 |
Initial Penalty |
4351.0 |
Final Order |
2022-03-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. At 1900 Copperstone Drive, Lot's A-F, Fleming Island, Florida: On or about November 9, 2021, the employer exposed employees to head injuries, in that protective helmets (hard hats) were not utilized by employees who worked beneath other employees, while performing roofing operations. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2022-03-02 |
Current Penalty |
2610.6 |
Initial Penalty |
4351.0 |
Final Order |
2022-03-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a. At 1900 Copperstone Drive, Lot's A-F, Fleming Island, Florida: On or about November 9, 2021, the employer exposed employees to eye injuries caused by air-born debris and flying objects, in that eye protection was not utilized, while a gas-powered blower was operated during the removal of an existing roof system. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2022-03-02 |
Current Penalty |
6090.6 |
Initial Penalty |
10151.0 |
Final Order |
2022-03-22 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. At 1900 Copperstone Drive, Lot's A-F, Fleming Island, Florida: On or about November 9, 2021, the employer exposed employees to fall hazards ranging from 10 to 30-foot, in that fall protection systems were not utilized by employees during the removal of an existing roof system. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2022-03-02 |
Current Penalty |
5221.2 |
Initial Penalty |
8702.0 |
Final Order |
2022-03-22 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed: a. At 1900 Copperstone Drive, Lot's A and E, Fleming Island, Florida: On or about November 9, 2021, the employer exposed employees to a 10-foot fall hazard, in that a 28-foot, aluminum extension ladder, consisting of two sections, was separated into two individual ladders and the flying section of the ladder, which did not have slip-resistant feet, was as used to access and egress the roof, which was a purpose other than the purpose for which the ladder was designed. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2022-03-02 |
Current Penalty |
5221.2 |
Initial Penalty |
8702.0 |
Final Order |
2022-03-22 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects were not immediately marked " Defective, Do not Use" and withdrawn from service: a. At 1900 Copperstone Drive, Lot's A-F, Fleming Island, Florida: On or about November 9, 2021, the employer exposed employees to fall hazards, in that the employer allowed employees to use an aluminum extension ladder that had a bend at the 5th rung and the 8th rung was cut through. |
|
|