Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-07-12
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2014-12-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-07-24 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about June 20, 2013, at the above addressed jobsite, employees were working on a scaffold that was not fully planked. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2013-07-24 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about June 20, 2013, at the above addressed jobsite, an employee was on a scaffold and the uprights which were on sandy soil, did not have mudsills. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2013-07-24 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about June 20, 2013, at the above addressed jobsite, employees did not have a ladder to access the scaffold. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 |
Issuance Date |
2013-07-24 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph: On or about June 20, 2013, at the above addressed jobsite, an employee was working on a scaffold which did not have guardrails. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2013-07-24 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about June 20, 2013, at the above referenced jobsite, the prefabricated frame scaffold did not have cross braces. |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-04-25
|
Emphasis |
L: EISAOF, L: FALL, P: FALL
|
Case Closed |
2015-01-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2013-07-19 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: On or about May 25, 2013, at the above addressed jobsite, employees were engaged in exterior molding installation work from an aerial lift at approximately 16 feet above ground level without a means of fall protection. |
|
|