Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-10-24
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-01-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2013-11-22 |
Abatement Due Date |
2013-12-03 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about October 22, 2013, the employee mixing cement was not wearing safety glasses, exposing himself to possible eye injuries. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-11-22 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights: a. On or about October 22, 2013, an employee applying stucco from the first level of the scaffold system that was not fully planked and the platform only had two planks with gaps, exposing the employee to a 6 feet fall hazard. Abatement Certification and Documentation are not required |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2013-11-22 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-01-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about October 22, 2013, front and left side of the home, the two buck high scaffold systems were erected in the sand did not have mudsills or base plates, exposing employees to crushing hazards. Abatement Certification and Documentation are not required |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2013-11-22 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-01-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a. On or about October 22, 2013, the employee accessed the first level of the scaffold sytem by climbing the rungs. The scaffold system was not equipped with a ladder, exposing the employee to a 6 feet fall hazard. Abatement Certification and Documentation are not required. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2013-11-22 |
Abatement Due Date |
2013-12-19 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-01-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a. On or about October 22, 2013, employees applying stucco on the front of the home were working on a scaffold system that was not erected under the supervision of a competent person. |
|
|