Search icon

SUPERIOR SERVICES GROUP CORP - Florida Company Profile

Company Details

Entity Name: SUPERIOR SERVICES GROUP CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

SUPERIOR SERVICES GROUP CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Oct 2012 (12 years ago)
Date of dissolution: 26 Sep 2014 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 26 Sep 2014 (10 years ago)
Document Number: P12000083316
FEI/EIN Number 46-1120469

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2671 NW 63 AVE, MARGATE, FL, 33063, US
Mail Address: 1231 S POWER LINE RD, POMPANO BEACH, FL, 33069, US
ZIP code: 33063
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CRUZ JAVIER E President 2671 NW 63 AVE, MARGATE, FL, 33063
CRUZ JAVIER E Agent 187 NW 91 TH AVE, MIAMI, FL, 33172

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2014-09-26 - -

Documents

Name Date
ANNUAL REPORT 2013-04-30
Domestic Profit 2012-10-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338997687 0418800 2013-04-09 1301 EAST ATLANTIC, POMPANO BEACH, FL, 33060
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-04-09
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2019-03-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-04-18
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 04-09-13, two employees were working on a scaffold that was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-04-18
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On or about 04-09-13, two employees were working on a scaffold which did not have a safe means of access.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-04-18
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. On or about 04-09-13, the scaffold was moved and erected without the presence or instruction of a competent person.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 G04
Issuance Date 2013-04-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. On or about 04-09-13, the scaffold was moved and erected without the presence or instruction of a competent person.
338549231 0418800 2013-01-24 1206 S FEDERAL HIGHWAY, DELRAY BEACH, FL, 33483
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-01-25
Emphasis L: FALL, P: FALL
Case Closed 2019-03-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-06-19
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a. On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a fabricated frame scaffold without using a means of conventional fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-06-19
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about January 24, 2013, at the above addressed job site, at the above addressed jobsite, an employee was exposed to a fall hazard while conducting concrete forming work from a fabricated frame scaffold that was not fully planked.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2013-06-19
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement: a. On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a defective fabricated frame scaffold that had separated end frames.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used: a. On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while gaining access to a fabricated frame scaffold which was not equipped with access ladders.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On or about January 24, 2013, at the above addressed job site, employees were exposed to a fall hazard while conducting concrete forming work from a fabricated frame scaffold that had not been inspected by a competent person.