Search icon

BECKER & ASSOCIATES CONSTRUCTION, INC. - Florida Company Profile

Company Details

Entity Name: BECKER & ASSOCIATES CONSTRUCTION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BECKER & ASSOCIATES CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 13 Sep 2012 (13 years ago)
Date of dissolution: 23 Sep 2022 (3 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2022 (3 years ago)
Document Number: P12000078044
FEI/EIN Number 460995806

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 56 EMERSON DR., PALM COAST, FL, 32164, US
Mail Address: 56 EMERSON DR., PALM COAST, FL, 32164, US
ZIP code: 32164
County: Flagler
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BECKER DONALD President 56 EMERSON DR., PALM COAST, FL, 32164
BECKER DONALD Agent 56 EMERSON DR., PALM COAST, FL, 32164

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2022-09-23 - -
REINSTATEMENT 2020-04-30 - -
REGISTERED AGENT NAME CHANGED 2020-04-30 BECKER, DONALD -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
REINSTATEMENT 2013-11-04 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -

Documents

Name Date
ANNUAL REPORT 2021-04-30
REINSTATEMENT 2020-04-30
ANNUAL REPORT 2018-04-30
ANNUAL REPORT 2017-04-28
ANNUAL REPORT 2016-04-28
ANNUAL REPORT 2015-04-29
ANNUAL REPORT 2014-04-28
REINSTATEMENT 2013-11-04
Domestic Profit 2012-09-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341341139 0419700 2016-03-16 5300 SOUTH ATLANTIC AVE, NEW SMYRNA BEACH, FL, 32169
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-03-16
Emphasis L: FALL, P: FALL
Case Closed 2017-05-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 A02 II E
Issuance Date 2016-04-06
Current Penalty 2100.0
Initial Penalty 2800.0
Final Order 2016-05-04
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) On or about March 16, 2016, employees traversing the stairwell to gain access to the 5th floor were exposed to electrical shock hazards because the temporary lights in the stairwell affixed to the handrails had missing cages resulting in broken and missing light bulbs that exposed the metal contacts of the socket.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 III
Issuance Date 2016-04-06
Current Penalty 1800.0
Initial Penalty 2400.0
Final Order 2016-05-04
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: a) On or about March 16, 2016 employees using power tools to set concrete form tables on the 5th floor were exposed to electrical shock hazards because the temporary flexible power cord in use was cut and spliced at the section before the adapter plugged into the outlet box. This splice exposed the wires by removing the insulation of the cord.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2016-04-06
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-05-04
Nr Instances 2
Nr Exposed 6
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a). On or about March 16, 2016 employees working on the project were exposed to falls in excess of 45 feet to the concrete below because the location of their jobbox tool box maintained on site was within 3 feet of the floor edge and was not protected by means of a guard rail or safety net. b). On or about March 16, 2016 employees using a Porta Potty temporary bathroom were exposed to fall hazards in excess of 35 feet to the ground below because the Porta Potty was positioned within 2 feet of the floor edge where no guardrails or safety nets were in place.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260502 B04
Issuance Date 2016-04-06
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-05-04
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(4): When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section was applied in a downward direction, the top edge of the guardrail deflected to a height less than 39 inches (1.0 m) above the walking/working level. a). On or about March 16, 2016 employees traversing the upper floors of a 5 story construction project were exposed to falls in excess of 45 feet to the concrete below because the cable guardrail system installed at the floor edges were loose and did not maintain a deflected height of 39 inches above the walking level.

Date of last update: 02 Apr 2025