347215972
|
0420600
|
2024-01-18
|
4773 58TH AVENUE NORTH SUITE D, SAINT PETERSBURG, FL, 33714
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-01-31
|
Case Closed |
2024-03-28
|
Related Activity
Type |
Complaint |
Activity Nr |
2116582 |
Safety |
Yes |
Health |
Yes |
|
|
339999336
|
0420600
|
2014-10-08
|
5843 CARRIER STREET N, SAINT PETERSBURG, FL, 33714
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-10-10
|
Case Closed |
2016-11-16
|
Related Activity
Type |
Referral |
Activity Nr |
898098 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100094 C04 I |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-12-10 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.94(c)(4)(i): The spray room, including floors, was not constructed of masonry, concrete, or other noncombustible material: a) Spray Room - There was a wood ceiling, wood walls and a built-in wood work bench in the room, on or about October 10, 2014. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100094 C04 II |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-12-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.94(c)(4)(ii): Spray rooms had combustible fire doors or shutters: a) Spray Room - There were two wood filter doors from the spray room into the main building, on or about October 10, 2014. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 D02 |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-12-10 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(d)(2): Spraying areas were not provided with adequate mechanical ventilation to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life was not endangered: a) Spray Room - Airflow in the vicinity of the sprayed piece was 20 to 30 feet per minute, on or about October 10, 2014. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100107 E02 |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-11-18 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift: a) Spray Room - There was a three-quarters full 55 gallon drum of flammable solvents stored in the room, on or about October 10, 2014. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100107 C06 |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-12-10 |
Current Penalty |
1760.0 |
Initial Penalty |
3520.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) Spray Room - There were 120 volt AC outlets, fluorescent lighting, snap switches, junction boxes and two electric fans in use, on or about October 10, 2014. Penhaglion, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.107(c)(6), which was contained in OSHA inspection number 982345, citation number 1, item number 1 and was affirmed as a final order on July 15, 2014, with respect to a workplace located at 5843 Carrier St. N, St. Petersburg, FL. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-11-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Spray Room - No respirator program was developed, on or about October 10, 2014. |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-11-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Spray Room - No medical evaluations were provided, on or about October 10, 2014. |
|
Citation ID |
03003 |
Citaton Type |
Other |
Standard Cited |
19100134 F01 |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-11-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Spray Room - No fit tests were provided, on or about October 10, 2014. |
|
Citation ID |
03004 |
Citaton Type |
Other |
Standard Cited |
19100134 G01 I A |
Issuance Date |
2014-10-22 |
Abatement Due Date |
2014-11-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) Spray Room - The spray painter had a beard, on or about October 10, 2014. |
|
|
339823452
|
0420600
|
2014-05-07
|
5843 CARRIER STREET N, SAINT PETERSBURG, FL, 33714
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-05-07
|
Emphasis |
L: EISAOF, L: EISAX
|
Case Closed |
2014-07-25
|
Related Activity
Type |
Inspection |
Activity Nr |
976332 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100107 C06 |
Issuance Date |
2014-06-30 |
Abatement Due Date |
2014-07-09 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-07-15 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: (a) spray paint room - a portable cord/plug Timex radio was inside the spray paint room; observed on or about 5/7/14. (b) spray paint room - three cord/plug floor fans used for ventilation were inside the spray paint room; observed on or about 5/7/14. (c) spray paint room - a Defiant surge protector used to supply electricity to items including, but not limited to, a radio and floor fans was inside the spray paint room; observed on or about 5/7/14. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 C07 |
Issuance Date |
2014-06-30 |
Abatement Due Date |
2014-07-09 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(c)(7): Electric lamps outside of, but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles: (a) spray paint room - there were four uncovered fluorescent light bulbs on the ceiling; observed on or about 5/7/14. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100157 E03 |
Issuance Date |
2014-06-30 |
Abatement Due Date |
2014-07-11 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) spray paint room - the fire extinguisher received its last maintenance check in June 2011; observed on or about 5/7/14. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-06-30 |
Abatement Due Date |
2014-07-25 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) at the workplace - there was not a written hazard communication program where employees were exposed to chemicals used in the painting process including, but not limited to, Defleet Essential single-stage enamel, paint thinners, Triangle Coatings metallic surfacer, and Sophisticated Finishes metallic surfacer; observed on or about 5/7/14. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2014-06-30 |
Abatement Due Date |
2014-07-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): (a) at the workplace - safety data sheets were not available for all the chemicals used at the workplace including, but not limited to, paint thinners, aging compounds, and metallic surfacers; observed on or about 5/7/14. |
|
|