Entity Name: | PROS ROOFING & CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
PROS ROOFING & CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 20 Aug 2012 (13 years ago) |
Date of dissolution: | 26 Sep 2014 (11 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 26 Sep 2014 (11 years ago) |
Document Number: | P12000071251 |
FEI/EIN Number |
APPLIED FOR
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2453 GANNON CIRCLE, PANAMA CITY, FL, 32405, US |
Mail Address: | PO BOX 1271, LYNN HAVEN, FL, 32444, US |
ZIP code: | 32405 |
County: | Bay |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
RAY RAYWAT P | President | PO BOX 1271, LYNN HAVEN, FL, 32444 |
HERNANDEZ DOMINGO | Vice President | 2635 HERNANDEZ LANE, CHIPLEY, FL, 32428 |
RAY RAYWAT P | Agent | 2453 GANNON CIRCLE, PANAMA CITY, FL, 32405 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2014-09-26 | - | - |
AMENDMENT | 2012-10-30 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2013-04-30 |
Amendment | 2012-10-30 |
Domestic Profit | 2012-08-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339822488 | 0419700 | 2014-06-24 | 3RD PLACE UNITS 10 -13, PANAMA CITY, FL, 32405 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 895179 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2014-08-04 |
Current Penalty | 1700.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-08-22 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about June 24, 2014, on the north side of the roof, employees working beneath employees tearing off roof shingles were not wearing hard hats, exposing employees to the hazard of being struck by falling debris. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2014-08-04 |
Current Penalty | 2900.0 |
Initial Penalty | 4900.0 |
Final Order | 2014-08-22 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. On or about June 24, 2014, on the north side of a 6/12 pitch roof, six employees tearing off and installing three tab shingles on the roof of a condominium complex were not protected from a 25 feet fall hazard by the use of a personal fall protection system. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2014-08-04 |
Current Penalty | 2900.0 |
Initial Penalty | 4900.0 |
Final Order | 2014-08-22 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about June 24, 2014, on the north side of the house, the ladder used to access the roof did not extend 3 feet above the upper landing surface, exposing employees to an 10 feet fall hazard. |