Search icon

G.I.D. CONSTRUCTION, INC. - Florida Company Profile

Company Details

Entity Name: G.I.D. CONSTRUCTION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

G.I.D. CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 10 Aug 2012 (13 years ago)
Date of dissolution: 27 Sep 2013 (12 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2013 (12 years ago)
Document Number: P12000069350
Address: 1390 NW 2ND STREET, APT. 6, MIAMI, FL, 33125
Mail Address: 1390 NW 2ND STREET, APT. 6, MIAMI, FL, 33125
ZIP code: 33125
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PENA ARNALDO President 1390 NW 2ND STREET APT.6, MIAMI, FL, 33125
PENA ARNALDO Agent 1390 NW 2ND STREET, MIAMI, FL, 33125

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -

Documents

Name Date
Domestic Profit 2012-08-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338968993 0418800 2013-03-21 2320 N. FEDERAL HWY, POMPANO BEACH, FL, 33062
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-03-21
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2019-01-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2013-07-03
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about March 21st 2013, at the above addressed job site, employees were exposed to fall hazards while working on a steep roof without fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2013-07-03
Abatement Due Date 2013-07-24
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-07-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about March 21st, 2013, at the above job site, employees were not knowledgeable in recognizing fall hazards while working near the edge of a commercial roof. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
338973357 0418800 2013-03-07 5800 NW 104 PATH, DORAL, FL, 33178
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2013-03-07
Emphasis L: EISAOF, P: FALL, L: FALL
Case Closed 2016-07-14

Related Activity

Type Inspection
Activity Nr 894759
Safety Yes
Type Inspection
Activity Nr 894656
Safety Yes
Type Inspection
Activity Nr 894752
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-04-05
Abatement Due Date 2013-04-11
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-06-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 03/07/2013, at the above addressed worksite, employees standing on a balcony did not have fall protection.
Citation ID 02001
Citaton Type Other
Standard Cited 19260701 B
Issuance Date 2013-04-05
Abatement Due Date 2013-04-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-06-07
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about, 03/07/2013, at the above addressed worksite, employees were exposed to multiple uncapped reinforcement rods on and near the balcony. NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.

Date of last update: 01 Apr 2025

Sources: Florida Department of State