339756199
|
0420600
|
2014-02-20
|
RAINBOW SPRINGS LOOP, GROVELAND, FL, 34736
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-02-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-11-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-06-12 |
Current Penalty |
6160.0 |
Initial Penalty |
6160.0 |
Final Order |
2014-07-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Roof - an employee was exposed to a fall of approximately 18 feet while decking the roof, on or about 2/20/14. MGB Construction, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 923538, citation number 1, item number 2 and was affirmed as a final order on 11/18/13, with respect to a workplace located at 1204 Legg Drive, Lot 1138, Apopka, FL. |
|
|
339528135
|
0420600
|
2013-12-18
|
1801 WP BALL BLVD., SANFORD, FL, 32771
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-12-18
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-11-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2014-01-02 |
Current Penalty |
1020.0 |
Initial Penalty |
1020.0 |
Final Order |
2014-02-24 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. Scaffold east area - ladder used for access to the welded frame scaffold was partially taken down and did not extend for completed access to the second level; employees used an endframe for access and were exposed up to a 13' 9" fall hazard. Violation observed on or about 12/18/13. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2014-01-02 |
Abatement Due Date |
2014-01-08 |
Current Penalty |
2040.0 |
Initial Penalty |
2040.0 |
Final Order |
2014-02-24 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a. Scaffold east and south walls - single cross bracing sections were used on open sides of platforms as both a mid and top rail during masonry operations and exposed employee(s) up to a 13' 9" fall hazard on a welded frame scaffold. Violation observed on or about 12/18/13. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2014-01-02 |
Abatement Due Date |
2014-02-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. Mixing area - employees that used 3M 8210 N95 dust masks during masonry operations were not provided the information contained in Appendix D of 29 CFR 1910.134. Violation observed on or about 12/18/13. |
|
|
339235384
|
0420600
|
2013-07-26
|
1204 LEGG DRIVE LOT 1138, APOPKA, FL, 32712
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-07-29
|
Emphasis |
L: EISAOF, L: FALL, P: FALL
|
Case Closed |
2017-11-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2013-10-22 |
Current Penalty |
2160.0 |
Initial Penalty |
2160.0 |
Final Order |
2013-11-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a). Inside the two story single family residence no guardrail was installed to protect the employees working on the second level where it was opened to the floor below exposing them to a 12-foot fall hazard as observed on or about July 26, 2013. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-10-22 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-11-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On the roof of the two story single family residence on Lot 1128 where employees were installing roof decking, no fall protection was being used to protect the three employees from an 18-foot fall hazard from the eave to the ground below as observed on or about July 26, 2013. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2013-10-22 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-19 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder. (a) At Lot 1138 of 1204 Legg Drive in the D.R. Horton development, the 20-foot multi-purpose extension ladder used by employees to gain access to the interior second floor landing of the single family residence was not positioned with the side rails 3 feet above the landing exposing them to a 15-foot fall hazard as observed on or about July 26, 2013. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 A02 |
Issuance Date |
2013-10-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-11-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii). (a). The employer did not assure that each employee installing roof sheeting on the roof of the two story single family residence at Lot-1138 were trained on fall hazards and the protective measures to implement while working at heights greater than 10 feet. |
|
|