340357870
|
0419700
|
2015-01-31
|
732 SCENIC GULF DRIVE, MIRAMAR BEACH, FL, 32550
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-01-31
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-11-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2015-02-19 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-04-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. On or about January 30, 2015, on the north side of the building, employees were working out of an aerial lift without a harness and lanyard attached to boom or basket. |
|
|
339988966
|
0419700
|
2014-10-07
|
732 SENIC GULF DR, MIRAMAR BEACH, FL, 32550
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-10-07
|
Emphasis |
L: FALL
|
Case Closed |
2019-01-17
|
Related Activity
Type |
Inspection |
Activity Nr |
999349 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
910263 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
998868 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1007326 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2014-11-17 |
Current Penalty |
2520.0 |
Initial Penalty |
4200.0 |
Final Order |
2014-12-29 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about Oct. 7, 2014, on the south side of the house, employees working on a jobsite installing framing material were using pneumatic nail guns and did not wear eye protection, exposing themselves to the hazard of being struck in the eye or face by flying debris. b. On or about Oct. 7, 2014, on the south side of the house, an employee working on a jobsite installing framing material was using an electric reciprocating saw and did not wear eye protection, exposing themselves to the hazard of being struck in the eye or face by flying debris. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 B02 |
Issuance Date |
2014-11-17 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-12-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. On or about Oct. 7, 2014, on the southeast side of the house, an employee installing framing was using 2 inch by 10 inch wood planks as a scaffold platform, exposing the employee to an 6 feet, 7 inch fall hazard. b. On or about Oct. 7, 2014, on the southwest side of the house, an employee installing framing was using 2 inch by 10 inch wood planks as a scaffold platform, exposing the employee to an 6 feet 1 inch fall hazard. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2014-11-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-12-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about Oct. 7, 2014, on the southeast side of the new construction building, the carpenter's scaffold did not have adequate firm foundations, exposing employees to a 6 feet 7 inch fall hazard. b. On or about Oct. 7, 2014, on the southwest side of the new construction building, the carpenter's scaffold did not have adequate firm foundations, exposing employees to a 6 feet 1 inch fall hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2014-11-17 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-12-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about Oct. 7, 2014, on the south side of the building, an employee stepped outside a window opening while building a frame structure for a structure was not protected from a 16 feet 3 inch fall hazard by the use of a personal fall protection system. b. On or about Oct. 7, 2014, on the south side of the building, an employee working on an edge while building a frame structure for a structure was not protected from a 11 feet 5 inch fall hazard by the use of a personal fall protection system. |
|
|
339817546
|
0419700
|
2014-06-06
|
5029 PRETTY WAY LOT 152, PANAMA CITY, FL, 32405
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-06-06
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 D |
Issuance Date |
2014-06-30 |
Current Penalty |
3080.0 |
Initial Penalty |
3080.0 |
Final Order |
2014-08-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe: a. On or about June 6, 2014, an employee was using a Makita circular saw, Serial number 1133177, Model No: 5007F to cut wood had a wood chip holding back the guard, exposing himself to amputation hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2014-06-30 |
Current Penalty |
5390.0 |
Initial Penalty |
5390.0 |
Final Order |
2014-08-18 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about June 6, 2014, an 8-foot Werner A-frame step ladder was used to gain access and exit from the trusses, exposing the employees to fall hazards. b. On or about June 6, 2014, a 6-foot Louisville A-frame step ladder was used to gain access and exit from the trusses, exposing the employees to fall hazards. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-06-30 |
Current Penalty |
10780.0 |
Initial Penalty |
10780.0 |
Final Order |
2014-08-18 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about June 6, 2014, employees sheathing a one-story home were not protected from falling 9 feet to the ground by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection. b. On or about June 6, 2014, the employee bracing trusses on a one-story home was not protected from falling 16 feet to the ground by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection method. The Cavazos Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 966142, citation number 01, item number 001 and was affirmed as a final order on June 9, 2014, with respect to a workplace located at 5007 Pretty Way, Lot 147, Panama City, Florida. |
|
|
339661423
|
0419700
|
2014-03-31
|
5007 PRETTY WAY LOT 147, PANAMA CITY, FL, 32405
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-04-03
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-08-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-05-05 |
Abatement Due Date |
2014-05-13 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-06-18 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about March 31, 2014, employees framing a two-story home were not protected from falling 10 feet 6-inches to the next level by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection method. b. On or about March 31, 2014, employees framing a two-story home were not protected from falling 18 feet 6-inches to the ground by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection method. c. On or about March 31, 2014, employees walking and/or working near the second floor level were not protected from falling 8 feet to the floor below by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection method. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2014-05-05 |
Abatement Due Date |
2014-05-13 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-06-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a. On or about March 31, 2014, the stairways leading to the next level did not have at least one handrail, exposing employees to an 8 feet 6-inch fall hazard. Abatement Certification and Documentation are required |
|
|