Entity Name: | M.C. MILLER CO., INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
M.C. MILLER CO., INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 14 Jun 2012 (13 years ago) |
Document Number: | P12000055973 |
FEI/EIN Number |
22-1777475
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
Mail Address: | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
ZIP code: | 32958 |
County: | Indian River |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Colucci Joseph | Director | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
Gargiule Lori A | Director | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
Savoca Augustine | Director | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
Hilberts Gwynedd | Director | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
Ditton Michael | Director | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
Gamez Ruben | Director | 11640 US HWY 1, SEBASTIAN, FL, 32958 |
EMMONS REBECCA F | Agent | The Modern One Bldg, VERO BEACH, FL, 329607701 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT ADDRESS CHANGED | 2016-03-08 | The Modern One Bldg, 2101 Indian River Blvd, Ste 200, VERO BEACH, FL 32960-7701 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-20 |
ANNUAL REPORT | 2024-01-17 |
ANNUAL REPORT | 2023-01-26 |
ANNUAL REPORT | 2022-01-31 |
ANNUAL REPORT | 2021-02-03 |
ANNUAL REPORT | 2020-03-02 |
ANNUAL REPORT | 2019-03-11 |
ANNUAL REPORT | 2018-01-17 |
ANNUAL REPORT | 2017-04-05 |
ANNUAL REPORT | 2016-03-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343664355 | 0418800 | 2018-11-06 | 11640 US HWY 1, SEBASTIAN, FL, 32958 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2019-04-15 |
Abatement Due Date | 2019-05-02 |
Current Penalty | 3978.0 |
Initial Penalty | 6630.0 |
Final Order | 2019-04-30 |
Nr Instances | 4 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the Clausing Lathe Model 5916 equipment was not guarded exposed an employee to a hand injury. b. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the Hardinge Lathe DSM-59 equipment was not guarded exposed an employee to a hand injury. c. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the Kalamazoo sander equipment was not guarded exposed an employee to a hand injury. d. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the BS-925 Metal cutting band saw exposed an employee to a hand injury. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100303 G01 |
Issuance Date | 2019-04-15 |
Abatement Due Date | 2019-05-02 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-04-30 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, electrical panel was blocked with a lathe machine and some boxes, impeding the access of the panel. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100304 B02 |
Issuance Date | 2019-04-15 |
Abatement Due Date | 2019-05-02 |
Current Penalty | 2386.8 |
Initial Penalty | 3978.0 |
Final Order | 2019-04-30 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, employees were exposed to an electrical shock while plugging into a multiple plug power strip outlet to energize drill presses and a X-ray machine. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100157 C04 |
Issuance Date | 2019-04-15 |
Abatement Due Date | 2019-05-02 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-04-30 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, a fire extinguisher located close to the restrooms was not fully charged. |
Date of last update: 01 Apr 2025