Search icon

M.C. MILLER CO., INC. - Florida Company Profile

Company Details

Entity Name: M.C. MILLER CO., INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

M.C. MILLER CO., INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 14 Jun 2012 (13 years ago)
Document Number: P12000055973
FEI/EIN Number 22-1777475

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 11640 US HWY 1, SEBASTIAN, FL, 32958
Mail Address: 11640 US HWY 1, SEBASTIAN, FL, 32958
ZIP code: 32958
County: Indian River
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Colucci Joseph Director 11640 US HWY 1, SEBASTIAN, FL, 32958
Gargiule Lori A Director 11640 US HWY 1, SEBASTIAN, FL, 32958
Savoca Augustine Director 11640 US HWY 1, SEBASTIAN, FL, 32958
Hilberts Gwynedd Director 11640 US HWY 1, SEBASTIAN, FL, 32958
Ditton Michael Director 11640 US HWY 1, SEBASTIAN, FL, 32958
Gamez Ruben Director 11640 US HWY 1, SEBASTIAN, FL, 32958
EMMONS REBECCA F Agent The Modern One Bldg, VERO BEACH, FL, 329607701

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2016-03-08 The Modern One Bldg, 2101 Indian River Blvd, Ste 200, VERO BEACH, FL 32960-7701 -

Documents

Name Date
ANNUAL REPORT 2025-01-20
ANNUAL REPORT 2024-01-17
ANNUAL REPORT 2023-01-26
ANNUAL REPORT 2022-01-31
ANNUAL REPORT 2021-02-03
ANNUAL REPORT 2020-03-02
ANNUAL REPORT 2019-03-11
ANNUAL REPORT 2018-01-17
ANNUAL REPORT 2017-04-05
ANNUAL REPORT 2016-03-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343664355 0418800 2018-11-06 11640 US HWY 1, SEBASTIAN, FL, 32958
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-11-06
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2019-05-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2019-04-15
Abatement Due Date 2019-05-02
Current Penalty 3978.0
Initial Penalty 6630.0
Final Order 2019-04-30
Nr Instances 4
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the Clausing Lathe Model 5916 equipment was not guarded exposed an employee to a hand injury. b. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the Hardinge Lathe DSM-59 equipment was not guarded exposed an employee to a hand injury. c. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the Kalamazoo sander equipment was not guarded exposed an employee to a hand injury. d. On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, the point of operation for the BS-925 Metal cutting band saw exposed an employee to a hand injury.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100303 G01
Issuance Date 2019-04-15
Abatement Due Date 2019-05-02
Current Penalty 2386.8
Initial Penalty 3978.0
Final Order 2019-04-30
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, electrical panel was blocked with a lathe machine and some boxes, impeding the access of the panel.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100304 B02
Issuance Date 2019-04-15
Abatement Due Date 2019-05-02
Current Penalty 2386.8
Initial Penalty 3978.0
Final Order 2019-04-30
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, employees were exposed to an electrical shock while plugging into a multiple plug power strip outlet to energize drill presses and a X-ray machine.
Citation ID 02001
Citaton Type Other
Standard Cited 19100157 C04
Issuance Date 2019-04-15
Abatement Due Date 2019-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-04-30
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: On or about 11/06/2018, jobsite located at 11640 US 1 Highway Sebastian, FL 32958, a fire extinguisher located close to the restrooms was not fully charged.