Entity Name: | FIRST DIMENSION WORK INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Profit Corporation
FIRST DIMENSION WORK INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 19 Jun 2012 (13 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 22 Jul 2022 (3 years ago) |
Document Number: | P12000055254 |
FEI/EIN Number |
45-5543327
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 9500 SW 165 TERRACE, MIAMI, FL 33157 |
Mail Address: | 9500 SW 165 TERRACE, MIAMI, FL 33157 |
ZIP code: | 33157 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
YARTU, IGNACIO | Agent | 9500 SW 165 TERRACE, MIAMI, FL 33157 |
YARTU, IGNACIO | President | 9500 SW 165 TERRACE, MIAMI, FL 33157 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REINSTATEMENT | 2022-07-22 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2020-09-25 | - | - |
REINSTATEMENT | 2019-11-19 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
REINSTATEMENT | 2017-11-07 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2017-09-22 | - | - |
REGISTERED AGENT NAME CHANGED | 2016-02-18 | YARTU, IGNACIO | - |
REINSTATEMENT | 2016-02-18 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2015-09-25 | - | - |
REINSTATEMENT | 2014-01-02 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-10 |
ANNUAL REPORT | 2023-03-23 |
REINSTATEMENT | 2022-07-22 |
REINSTATEMENT | 2019-11-19 |
ANNUAL REPORT | 2018-04-18 |
REINSTATEMENT | 2017-11-07 |
REINSTATEMENT | 2016-02-18 |
REINSTATEMENT | 2014-01-02 |
Domestic Profit | 2012-06-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347331860 | 0418800 | 2024-03-05 | 18505 HOMESTEAD AVE, MIAMI, FL, 33157 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-08-22 |
Abatement Due Date | 2024-09-18 |
Current Penalty | 4610.0 |
Initial Penalty | 4610.0 |
Final Order | 2024-09-17 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about March 5, 2024, at 18505 Homestead Avenue, Miami, Florida, employees were exposed to an approximated 20-foot fall hazard while Installing roofing materials without a fall protection system. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2024-08-22 |
Abatement Due Date | 2024-09-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-09-17 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: On or about March 5, 2024, at 18505 Homestead Avenue, Miami, Florida, the employer did not prepare a written fall training certification record pursuant to this standard. |
Inspection Type | Unprog Rel |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2013-05-31 |
Emphasis | L: FALL |
Case Closed | 2014-05-02 |
Related Activity
Type | Inspection |
Activity Nr | 909745 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2013-10-25 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-12-18 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about May 31, 2013, at the above addressed jobsite, an employee was observed installing/removing roofing material from a rooftop (trash collection area) without the use of conventional fall protection, or without a safety monitoring system alone. b. On or about May 31, 2013, at the above addressed jobsite, an employee was observed installing/removing roofing material from a rooftop (storage room area) without the use of conventional fall protection, or without a safety monitoring system alone. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260502 D15 |
Issuance Date | 2013-10-25 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-12-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a. On or about May 31, 2013, at the above addressed jobsite, an employee was installing/removing roofing material from a rooftop, for which the anchorage points for the personal fall arrest system, was not capable of supporting at least 5,000 pounds. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-10-25 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-12-18 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about May 31, 2013, at the above addressed jobsite, an employee was using a portable metal extension ladder to gain access to a roof-top (trash collection area), which was not extended at least three feet above the upper landing surface. b. On or about May 31, 2013, at the above addressed jobsite, an employee was using a portable metal extension ladder to gain access to a roof-top (storage room area), which was not extended at least three feet above the upper landing surface. |
Date of last update: 22 Feb 2025
Sources: Florida Department of State