Entity Name: | FREDY DRYWALL INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
FREDY DRYWALL INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 21 May 2012 (13 years ago) |
Date of dissolution: | 27 Sep 2013 (12 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2013 (12 years ago) |
Document Number: | P12000046766 |
Address: | 5931 WINCHESTER ISLE ROAD, ORLANDO, FL, 32829, US |
Mail Address: | 5931 WINCHESTER ISLE ROAD, ORLANDO, FL, 32829, US |
ZIP code: | 32829 |
County: | Orange |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
PAUCAR FREDY R | President | 5931 WINCHESTER ISLE ROAD, ORLANDO, FL, 32829 |
PAUCAR FREDY R | Agent | 5931 WINCHESTER ISLE ROAD, ORLANDO, FL, 32829 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2013-09-27 | - | - |
Name | Date |
---|---|
Domestic Profit | 2012-05-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337262026 | 0420600 | 2012-11-07 | 12001 COLLEGIATE WAY, ORLANDO, FL, 32817 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 726401 |
Safety | Yes |
Type | Inspection |
Activity Nr | 726303 |
Safety | Yes |
Type | Inspection |
Activity Nr | 726101 |
Safety | Yes |
Type | Inspection |
Activity Nr | 726002 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2012-11-23 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-12-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a. At the site, employees were exposed to a fall hazard 12 feet to the ground below when using a Genie S-40 aerial lift during metal framing operations. A fall arrest system such as a full body harness or a body belt used as a restraint system was not used by employees in the basket of the aerial lift. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2012-11-23 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-12-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. At the site, employees were not protected from falling to the ground while installing metal framing. An employee was exposed to a fall hazard 12 feet high while standing on a piece of plywood placed between the rafters wile installing metal framing at the entrance of the building. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2012-11-23 |
Abatement Due Date | 2013-01-11 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-12-21 |
Nr Instances | 1 |
Nr Exposed | 4 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a written safety and health program to address the company policy on safety as well as the employer/employee responsibilities. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19260454 A |
Issuance Date | 2012-11-23 |
Abatement Due Date | 2013-01-11 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-12-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards as required by paragraph (a)(1)-(5) of this section: a. At the site, employees were installing metal framing at the entrance of the building using an aerial lift (elevated scaffold platform). Employees involved in using aerial platforms were not provided training and education in the following: 1. The nature of fall hazards and any falling object hazards. 2. The correct procedures for dealing with erecting, maintaining, and disassembling the fall protection system and falling object protection system being used. 3. The proper use of the scaffold, and the proper handling of material on the scaffold. 4. The maximum intended load and load carrying capacities of the scaffold. 5. Any other pertinent requirements of Subpart "L" (Scaffolds) under 29 CFR 1926. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19260503 A01 |
Issuance Date | 2012-11-23 |
Abatement Due Date | 2013-01-11 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-12-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. At the site, employees working at the entrance of the building installing metal framing were exposed to a 12 foot fall hazard and were not provided training and education relating to fall protection, hazard recognition, procedures to be followed to minimize these hazards and the proper use and limitation of fall protection equipment and fall protection systems. The employer did not train employees to inspect their fall protection equipment in order to assure that equipment is in good condition and are functioning properly. |