Search icon

DECOR CONSTRUCTION, INC

Company Details

Entity Name: DECOR CONSTRUCTION, INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 25 Apr 2012 (13 years ago)
Date of dissolution: 23 Sep 2016 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (8 years ago)
Document Number: P12000039151
FEI/EIN Number 45-5178492
Address: 395 Twin Lakes Lane, Destin, FL 32541
Mail Address: 395 Twin Lakes Lane, Destin, FL 32541
ZIP code: 32541
County: Okaloosa
Place of Formation: FLORIDA

Agent

Name Role Address
RAC, ANDREEA MRS Agent 395 Twin Lakes Lane, Destin, FL 32541

President

Name Role Address
RAC, ANDREEA MRS President 395 Twin Lakes Lane, Destin, FL 32541

Vice President

Name Role Address
RAC, ENORIAN SMR Vice President 395 Twin Lakes Lane, Destin, FL 32541

Secretary

Name Role Address
RAC, ION MR Secretary 96 WINDRIFT DRIVE, MIRAMAR BEACH, FL 32550

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 No data No data
CHANGE OF PRINCIPAL ADDRESS 2013-03-28 395 Twin Lakes Lane, Destin, FL 32541 No data
CHANGE OF MAILING ADDRESS 2013-03-28 395 Twin Lakes Lane, Destin, FL 32541 No data
REGISTERED AGENT ADDRESS CHANGED 2013-03-28 395 Twin Lakes Lane, Destin, FL 32541 No data

Documents

Name Date
ANNUAL REPORT 2015-03-11
ANNUAL REPORT 2014-03-05
ANNUAL REPORT 2013-03-28
Domestic Profit 2012-04-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340114578 0419700 2014-12-03 4660 DESTINY WAY, DESTIN, FL, 32540
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-12-03
Emphasis P: FALL, L: FALL
Case Closed 2015-11-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-12-10
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2015-01-06
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about December 3, 2014, on the south side of a residential house, an employees cutting waterproof siding material was not protected from a 23 feet 6 inch fall hazard by the use of a personal fall protection system.

Date of last update: 22 Feb 2025