Entity Name: | COLORS CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
COLORS CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 12 Mar 2012 (13 years ago) |
Date of dissolution: | 27 Sep 2013 (11 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2013 (11 years ago) |
Document Number: | P12000024559 |
Address: | 5002 ISLAND CLUB DR, TAMARAC, FL, 33319 |
Mail Address: | 5002 ISLAND CLUB DR, TAMARAC, FL, 33319 |
ZIP code: | 33319 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
VASQUEZ JOSE A | Director | 5002 ISLAND CLUB DR, TAMARAC, FL, 33319 |
VASQUEZ JOSE A | Agent | 5002 ISLAND CLUB DR, TAMARAC, FL, 33319 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2013-09-27 | - | - |
Name | Date |
---|---|
Domestic Profit | 2012-03-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
336148382 | 0419700 | 2012-08-30 | 3733 VALVERDE CIRCLE, JACKSONVILLE, FL, 32224 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2012-09-27 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-11-21 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a. On or about August 30, 2012, employees cutting wood on the ground and throwing wood pieces to the carpenters doing the roof sheathing of a residential house were not wearing hardhats, exposing themselves to head injuries. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2012-09-27 |
Current Penalty | 2400.0 |
Initial Penalty | 2400.0 |
Final Order | 2012-11-21 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a. On or about August 30, 2012, two employees installing roof sheathing on a 7:12 pitch residential roof were not being protected by a guardrail system, safety net or personal fall arrest system, exposing themselves to a 10.5 feet fall hazard. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2012-09-27 |
Current Penalty | 1200.0 |
Initial Penalty | 1200.0 |
Final Order | 2012-11-21 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about August 30, 2012, in the North West side of the residential roof, an employee doing roof sheathing on a 7:12 pitch roof set up the Louisville 20-foot fiberglass extension ladder at 2 feet above the landing surface, exposing himself to a 10.5 feet fall hazard. b. On or about August 30, 2012, in the South West side of the residential roof, an employee doing roof sheathing on a 7:12 pitch roof set up the Werner 24-foot aluminum extension ladder at 1 ? feet above the landing surface, exposing himself to a 10.5 feet fall hazard. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2012-07-31 |
Emphasis | L: SILICA |
Case Closed | 2013-01-08 |
Related Activity
Type | Complaint |
Activity Nr | 467651 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100132 E |
Issuance Date | 2012-08-29 |
Abatement Due Date | 2012-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-09-25 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(e): The employer did not ensure that employees were not using defective or damaged personal protective equipment in the workplace. On or about 7/27/2012, at 2156 Arielle Dr. in the city of Naples, FL; employees engaged in concrete paver installation were using damaged personal protective equipment such as protective footwear. NOTE: CERTIFICATION OF ABATEMENT MUST BE SUBMITTED FOR THIS ITEM. |
Inspection Type | Fat/Cat |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2012-07-26 |
Emphasis | L: FALL |
Case Closed | 2017-02-23 |
Related Activity
Type | Accident |
Activity Nr | 469076 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2013-01-24 |
Abatement Due Date | 2013-01-30 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: On or about July 26, 2012 at the above addressed jobsite, employees were exposed to a fall hazard of approximately thirty (30') feet while working from an aerial lift without fall protection. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2013-01-24 |
Abatement Due Date | 2013-01-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-02-15 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety nets systems, or personal fall arrest systems: On or about July 26, 2012 at the above addressed jobsite, employees were exposed to a fall hazard of approximately 30 feet when they detached their safety harnesses and climbed out of a boom lift onto a ledge located above the windows of the building. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2013-01-24 |
Abatement Due Date | 2013-02-05 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. On or about July 26, 2012 at the above addressed jobsite, employees were not trained on the proper use of an aerial lift and/or the use of fall protection. |