336226386
|
0419700
|
2012-09-05
|
1812 DUNLAWTON, PORT ORANGE, FL, 32127
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-05
|
Emphasis |
L: FALL
|
Case Closed |
2018-09-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2012-10-18 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2012-12-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Variance |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a. On or about September 5, 2012, employees working from a Genie Lift (618130) at a height of approximately 12 feet from the ground without fall protection, exposing employees to a fall hazard. |
|
|
336208202
|
0418800
|
2012-08-31
|
8098 NW 30TH STREET BLDG #17, COOPER CITY, FL, 33024
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-05
|
Emphasis |
L: FALL, L: EISAOF
|
Case Closed |
2018-09-05
|
Related Activity
Type |
Inspection |
Activity Nr |
624838 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2012-10-04 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-02-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 8/31/12, at 8098 NW 30th Street, Bldg #17, in the city of Cooper City, workers were installing cement blocks from a scaffold approximately 13' above ground level where the working levels of the scaffold were not fully planked. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2012-10-04 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-02-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 8/31/12, at 8098 NW 30th Street, Bldg #17, in the city of Cooper City, workers were installing cement blocks from a scaffold approximately 13' above ground level whereas the employees did not have a means of egress to and from the scaffold. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2012-10-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-02-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 8/31/12, at 8098 NW 30th Street, Bldg #17, in the city of Cooper City, workers were installing cement blocks from a scaffold approximately 13' above ground level whereas the employer did not ensure the scaffold and scaffold components were inspected before each work shift. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2012-10-04 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-02-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: On 8/31/2012, at 8098 NW 30th Street, in the city of Cooper City, Florida, employees were installing cement blocks on a scaffold approximately 13' above ground level whereas the scaffold did not have end rails on both ends of the scaffold. |
|
|
336277983
|
0418800
|
2012-08-31
|
2600 DAVIE ROAD, DAVIE, FL, 33324
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-31
|
Emphasis |
L: FALL, L: EISAOF
|
Case Closed |
2018-08-29
|
Related Activity
Type |
Complaint |
Activity Nr |
544070 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2012-10-01 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-10-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 8/31/12, at 2600 Davie Road, in the city of Davie, Florida, an employee was exposed to an 11' fall hazard while leveling the cement on a tie beam. |
|
|
335987392
|
0420600
|
2012-08-24
|
1620 CENTRAL FLORIDA PARKWAY, ORLANDO, FL, 32837
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-08-24
|
Emphasis |
L: FALL
|
Case Closed |
2016-02-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2012-08-30 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2012-09-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a. North side of building - a ladder was not provided for safe access to and from the tube and coupler scaffold; therefore, exposing an employee to an approximate 9 ft fall hazard. Violation observed on or about 08/24/12. |
|
|
334416740
|
0418800
|
2012-05-17
|
8669 N.W. 36TH STREET, DORAL, FL, 33166
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-05-17
|
Emphasis |
L: FALL
|
Case Closed |
2018-08-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2012-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2012-08-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: On or about 05/17/2012, at 8669 NW 36th Street, Dorall, Fl. an employee was working from an aerail lift without fall protection means. The employee was exposed to a fall hazard of approximately 25 feet to the ground. |
|
|