Search icon

FATHER & SON ROOFING INC. - Florida Company Profile

Company Details

Entity Name: FATHER & SON ROOFING INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FATHER & SON ROOFING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 14 Nov 2011 (13 years ago)
Last Event: AMENDMENT
Event Date Filed: 16 Mar 2012 (13 years ago)
Document Number: P11000098527
FEI/EIN Number 32-0359977

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5012 NATHAN HALE RD, JACKSONVILLE, FL, 32221
Mail Address: 5012 NATHAN HALE RD, JACKSONVILLE, FL, 32221
ZIP code: 32221
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BROWN JOHN A Vice President 7542 TAURUS CIRCLE W., JACKSONVILLE, FL, 32222
Brown Riley Director 15836 Dusty Rd, Jacksonville, FL, 32234
BROWN WALTER E President 5012 NATHAN HALE RD., JACKSONVILLE, FL, 32221
BROWN JOHN A Director 7542 TAURUS CIRCLE W., JACKSONVILLE, FL, 32222
BROWN WALTER E Agent 5012 NATHAN HALE RD, JACKSONVILLE, FL, 32221

Events

Event Type Filed Date Value Description
AMENDMENT 2012-03-16 - -

Documents

Name Date
ANNUAL REPORT 2025-02-01
ANNUAL REPORT 2024-03-06
ANNUAL REPORT 2023-02-10
ANNUAL REPORT 2022-02-01
ANNUAL REPORT 2021-04-10
ANNUAL REPORT 2020-02-18
ANNUAL REPORT 2019-04-18
ANNUAL REPORT 2018-01-24
ANNUAL REPORT 2017-04-24
AMENDED ANNUAL REPORT 2016-11-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346884984 0419700 2023-08-01 802 MCDUFF AVENUE SOUTH, JACKSONVILLE, FL, 32205
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-08-01
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2023-09-06
Current Penalty 4419.0
Initial Penalty 4419.0
Final Order 2023-11-20
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles: a) An employee operating a debris blower is not being protected from eye injury hazards by the appropriate eye or face protection: The employer fails to assure effective protection against eye or face hazards from flying particles, as required by the standard, as demonstrated on or about August 1, 2013, when an employee blowing debris from a roof of a residence, located at 802 McDuff Avenue South, Jacksonville, Florida 32205, is exposed to struck-by hazards, in that eye protection is not utilized. Father and Son Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1), which was contained in OSHA inspection number 1433729, citation number 02, item number 001 and was affirmed as a final order on May 21, 2020, with respect to a workplace located at 5577 Old Middleburg Road, Jacksonville, Florida 32210.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2023-09-06
Current Penalty 10313.0
Initial Penalty 10313.0
Final Order 2023-11-20
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Employees performing roofing operations at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls as required by the standard, as demonstrated on or about August 1, 2023, when three employees were removing the existing roofing system from a residence located at 802 McDuff Avenue South, Jacksonville, Florida 32205, while exposed to the hazard of a 16-foot fall to the ground, in that no form of fall protection systems are in place or in use. Father and Son Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1433729, citation number 01, item number 001 and was affirmed as a final order on May 21, 2020, with respect to a workplace located at 5577 Old Middleburg Road, Jacksonville, Florida 32210.

Date of last update: 02 Apr 2025