Entity Name: | GARP CONSTRUCTION GROUP INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
GARP CONSTRUCTION GROUP INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 10 Nov 2011 (13 years ago) |
Document Number: | P11000097871 |
FEI/EIN Number |
453809986
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 8290 NW 66 ST, MIAMI, FL, 33166, US |
Mail Address: | 7530 SW 36 ST, MIAMI, FL, 33155, US |
ZIP code: | 33166 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ARIAS FERNANDO J | President | 7530 SW 36ST, MIAMI, FL, 33155 |
PEREZ JAVIER A | Vice President | 7530 SW 36 ST, MIAMI, FL, 33155 |
ARIAS FERNANDO J | Agent | 7530 SW 36 ST, MIAMI, FL, 33155 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2024-02-28 | 8290 NW 66 ST, MIAMI, FL 33166 | - |
CHANGE OF MAILING ADDRESS | 2024-02-28 | 8290 NW 66 ST, MIAMI, FL 33166 | - |
REGISTERED AGENT ADDRESS CHANGED | 2024-02-28 | 7530 SW 36 ST, MIAMI, FL 33155 | - |
REGISTERED AGENT NAME CHANGED | 2014-02-28 | ARIAS, FERNANDO JR | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J16000725832 | TERMINATED | 1000000725853 | MIAMI-DADE | 2016-11-02 | 2026-11-10 | $ 367.35 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, MIAMI SERVICE CENTER, 8175 NW 12TH ST STE 119, DORAL FL331261828 |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-08 |
ANNUAL REPORT | 2024-02-28 |
ANNUAL REPORT | 2023-01-26 |
ANNUAL REPORT | 2022-02-21 |
AMENDED ANNUAL REPORT | 2021-09-02 |
ANNUAL REPORT | 2021-01-11 |
AMENDED ANNUAL REPORT | 2020-11-18 |
ANNUAL REPORT | 2020-02-03 |
ANNUAL REPORT | 2019-02-07 |
ANNUAL REPORT | 2018-01-29 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343128716 | 0418800 | 2018-05-01 | 18831 BISCAYNE BLVD, AVENTURA, FL, 33180 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1333591 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 F15 |
Issuance Date | 2018-08-06 |
Abatement Due Date | 2018-08-30 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2018-10-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph: On or about 5/1/2018, at 18831 Biscayne Blvd, in the city of Aventura, an employee positioned a 12ft fiberglass step ladder on top of a 5ft rolling scaffold to access a commercial roof exposing himself to a fall hazard of more than 10ft. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260452 W02 |
Issuance Date | 2018-08-06 |
Abatement Due Date | 2018-08-30 |
Current Penalty | 3326.0 |
Initial Penalty | 3326.0 |
Final Order | 2018-10-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: On or about 5/1/2018, at 18831 Biscayne Blvd, in the city of Aventura, the employer did not ensure an employee secured the wheels of a rolling scaffold., exposing the worker to a 5-foot fall hazard. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260454 A03 |
Issuance Date | 2018-08-06 |
Abatement Due Date | 2018-09-21 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2018-10-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a)(3): The employer did not train each employee who performs work on a scaffold, by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards, including the proper use of the scaffold and the proper handling of materials on the scaffold: On or about 5/1/2018, at 18831 Biscayne Blvd, in the city of Aventura, the employer did not ensure an employee was adequately trained to recognize the hazards associated with rolling scaffolds and to understand the procedures to control or minimize those hazards. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19030019 D01 |
Issuance Date | 2019-01-14 |
Abatement Due Date | 2019-03-04 |
Current Penalty | 311.0 |
Initial Penalty | 311.0 |
Final Order | 2019-02-11 |
Nr Instances | 2 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. a) On or about 01/10/2019, the employer failed to submit certification of corrective action for citation 1 item 1 issued on 08/06/2018 with an abatement due date of 08/30/2018. b) On or about 01/10/2019, the employer failed to submit certification of corrective action for citation 1 item 2 issued on 08/06/2018 with an abatement due date of 08/30/2018. c) On or about 01/10/2019, the employer failed to submit certification of corrective action for citation 1 item 3 issued on 08/06/2018 with an abatement due date of 08/30/2018. |