Search icon

EAST COAST WHOLESALE ALUMINUM PRODUCTS, INC. - Florida Company Profile

Company Details

Entity Name: EAST COAST WHOLESALE ALUMINUM PRODUCTS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

EAST COAST WHOLESALE ALUMINUM PRODUCTS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 17 Aug 2011 (14 years ago)
Document Number: P11000073538
FEI/EIN Number 453015969

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1500 Avenue R, Riviera Beach, FL, 33404, US
Mail Address: 1500 Avenue R, Riviera Beach, FL, 33404, US
ZIP code: 33404
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MILLER GREGORY S President 1500 Avenue R, Riviera Beach, FL, 33404
MILLER GREGORY S Director 1500 Avenue R, Riviera Beach, FL, 33404
MILLER GREGORY S Treasurer 1500 Avenue R, Riviera Beach, FL, 33404
MILLER GREGORY S Agent 1500 Avenue R, Riviera Beach, FL, 33404

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2021-04-09 1500 Avenue R, 100, Riviera Beach, FL 33404 -
CHANGE OF MAILING ADDRESS 2021-04-09 1500 Avenue R, 100, Riviera Beach, FL 33404 -
REGISTERED AGENT ADDRESS CHANGED 2021-04-09 1500 Avenue R, 100, Riviera Beach, FL 33404 -

Documents

Name Date
ANNUAL REPORT 2024-03-13
ANNUAL REPORT 2023-04-03
ANNUAL REPORT 2022-03-25
ANNUAL REPORT 2021-04-09
ANNUAL REPORT 2020-03-19
ANNUAL REPORT 2019-04-05
ANNUAL REPORT 2018-04-11
ANNUAL REPORT 2017-04-05
ANNUAL REPORT 2016-03-29
ANNUAL REPORT 2015-04-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343060513 0418800 2018-04-03 8400 GARDEN ROAD SUITE A-2, WEST PALM BEACH, FL, 33404
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2018-04-03
Case Closed 2018-08-29

Related Activity

Type Complaint
Activity Nr 1269897
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2018-04-05
Abatement Due Date 2018-04-26
Current Penalty 1663.0
Initial Penalty 1663.0
Final Order 2018-04-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about April 3rd, 2018, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employer did not establish and implement a written respiratory protection program for employees who were required to wear respiratory protection such as NIOSH approved brand 3M, model 6000, half face elastomeric respirator, model 6000 with combined filters for organic vapors and N95 particulate pre-filter.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2018-04-05
Abatement Due Date 2018-04-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about April 3rd, 2018, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employer did not provide a medical evaluation for employees who are required to wear tight-fitting respirators type 3M model 6000, when performing grinding, sanding and painting of aluminum surfaces preparation.
Citation ID 01001C
Citaton Type Other
Standard Cited 19100134 F01
Issuance Date 2018-04-05
Abatement Due Date 2018-04-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about April 3rd, 2018, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employer did not provide a fit test for employees who are required to wear tight-fitting respirators type 3M model 6000, when performing grinding, sanding and painting of aluminum surfaces preparation.
Citation ID 01001D
Citaton Type Other
Standard Cited 19100134 G01 I A
Issuance Date 2018-04-05
Abatement Due Date 2018-04-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: On or about April 3rd, 2018, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employees were required to use tight-fitting respirators type 3M model 6000 and also were allowed to have facial hair that came between the sealing surface of the facepiece and the face providing poor or no seal to the respirator.
Citation ID 01001E
Citaton Type Other
Standard Cited 19100134 K01 I
Issuance Date 2018-04-05
Abatement Due Date 2018-04-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(1)(i): The employer did not ensure that each employee could demonstrate knowledge of why the respirator was necessary and how improper fit, usage, or maintenance could compromise the protective effect of the respirator: On or about April 3rd, 2018, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employer did not ensure that each employee could demonstrate knowledge of why the respirator was necessary, proper fit, usage, or maintenance for employees using a tight-fitting half face elastomeric respirator such as NIOSH approved brand 3M, model 6000.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2018-04-05
Abatement Due Date 2018-04-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about April 3rd, 2018, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employer did not provide effective training to employees about the chemical hazards such as but not limited to Prime 94 (Cyclohexane) and Acetone used while performing grinding, sanding, polishing and painting operations.
342685385 0418800 2017-10-05 8400 GARDEN ROAD SUITE A-2, WEST PALM BEACH, FL, 33404
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-10-05
Emphasis L: FORKLIFT
Case Closed 2018-07-13

Related Activity

Type Complaint
Activity Nr 1269897
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100178 L01 I
Issuance Date 2018-04-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-05-01
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about October 5th, 2017, at the site located at 8400 Garden Rd, Ste. A-2, FL 33404, the employer did not ensure that employees operating a forklift brand Toyota, Model SFGC25, had successfully completed the training required.

Date of last update: 03 Apr 2025

Sources: Florida Department of State