Search icon

KARR BROTHERS DRYWALL, INC. - Florida Company Profile

Company Details

Entity Name: KARR BROTHERS DRYWALL, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

KARR BROTHERS DRYWALL, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 10 Jun 2011 (14 years ago)
Last Event: AMENDMENT
Event Date Filed: 08 Jul 2011 (14 years ago)
Document Number: P11000054431
FEI/EIN Number 452506750

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3550 WORK DRIVE, B-9, FORT MYERS, FL, 33916
Mail Address: 3550 WORK DRIVE, B-9, FORT MYERS, FL, 33916
ZIP code: 33916
County: Lee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
KARR REGINO President 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR REGINO Director 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR ROEL Vice President 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR ROEL Treasurer 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR ROEL Director 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR REYNOL G Vice President 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR REYNOL G Secretary 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR REYNOL G Director 3550 WORK DRIVE STE. B-9, FORT MYERS, FL, 33916
KARR ROEL Agent 3550 WORK DRIVE, FORT MYERS, FL, 33916

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G11000057420 FOUR RK CONSTRUCTION GROUP ACTIVE 2011-06-10 2026-12-31 - 3550 WORK DRIVE, STE B-9, FORT MYERS, FL, 33916

Events

Event Type Filed Date Value Description
AMENDMENT 2011-07-08 - -

Documents

Name Date
ANNUAL REPORT 2024-01-17
ANNUAL REPORT 2023-01-17
ANNUAL REPORT 2022-04-20
ANNUAL REPORT 2021-01-15
ANNUAL REPORT 2020-06-11
ANNUAL REPORT 2019-02-12
ANNUAL REPORT 2018-01-31
ANNUAL REPORT 2017-02-20
ANNUAL REPORT 2016-02-25
ANNUAL REPORT 2015-03-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343768909 0418800 2019-02-07 710 SOLL STREET, NAPLES, FL, 34109
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-02-08
Emphasis P: FALL, L: FALL
Case Closed 2023-04-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2019-07-01
Abatement Due Date 2019-07-26
Current Penalty 2897.0
Initial Penalty 4376.0
Final Order 2019-07-22
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about 2/7/19, at 710 Soll Street, Naples, FL, the employer did not instruct each employee in the recognition and avoidance of unsafe conditions whereas employees were exposed to fall, impalement, and struck-by hazards while installing sheathing on a residential roof. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-07-01
Current Penalty 2069.0
Initial Penalty 3126.0
Final Order 2019-07-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee was using eye protection when exposed to eye or face hazards from flying particles: On or about 2/7/19, at 710 Soll Street, Naples, FL, employees were exposed to struck-by hazards while using a circular saw to cut plywood and pneumatic nail gun to install sheathing on a residential roof.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-07-01
Abatement Due Date 2019-07-26
Current Penalty 2897.0
Initial Penalty 4376.0
Final Order 2019-07-22
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 2/7/19, at 710 Soll Street, Naples, FL, employees installing sheathing on a residential roof were exposed to fall hazards due to lack of fall protection equipment. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2019-07-01
Current Penalty 2069.0
Initial Penalty 3126.0
Final Order 2019-07-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: On or about 2/7/19, at 710 Soll Street, Naples, FL, employees installing sheathing on a residential roof were exposed to impalement hazards due to lack of protective caps on rebar located on the ground level below the roof.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2019-07-01
Current Penalty 2068.0
Initial Penalty 3126.0
Final Order 2019-07-22
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about 2/7/19, at 710 Soll Street, Naples, FL, employees were using a stepladder in a closed position exposing themselves to a fall hazard due to using the ladder in a manner that it is not designed to be used.
339602393 0420600 2014-02-25 3300 BONITA BEACH RD., BONITA SPRINGS, FL, 34134
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-02-25
Emphasis L: FALL, L: EISAX, L: EISAOF, P: FALL
Case Closed 2014-03-21

Related Activity

Type Complaint
Activity Nr 873087
Safety Yes
Health Yes
Type Inspection
Activity Nr 960870
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-03-13
Abatement Due Date 2014-03-20
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-03-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.: a) For the jobsite at 3300 Bonita Beach Rd., Bonita Springs, FL 33716, as observed on or about 02/25/2014, as the controlling contractor for the stucco work, Karr Brothers Drywall, Inc. did not ensure that guardrails were in place on scaffolding working levels, exposing employees to fall hazards for up to 21 feet to the ground below.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-03-13
Abatement Due Date 2014-03-20
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-03-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) For the jobsite at 3300 Bonita Beach Rd., Bonita Springs, FL 33716, as observed on or about 02/25/2014, a ladder for safe access and exiting of scaffolding was not present. As the controlling contractor for the stucco work, Karr Brothers Drywall, Inc. did not ensure that a ladder was present for the scaffolding, and employees of Karr Brothers Drywall, Inc. were also exposed to hazards due to the missing ladder for the scaffolding and were observed to climb the scaffolding frame and cross braces since there was no access ladder.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 E09 I
Issuance Date 2014-03-13
Abatement Due Date 2014-03-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(9)(i): The employer did not provide safe means of access for each employee erecting or dismantling a scaffold: a) At the jobsite at 3300 Beach Rd., Bonita Springs, FL 34134, as observed on or about 02/25/2014, employees engaged in dismantling scaffolding were not provided with a safe means of ladder access. Employees were observed to be removing planking from scafdfolding with its structure intact, and had to climb the scaffold frame and cross braces since there was no ladder to access the level they were working on.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 E09 IV
Issuance Date 2014-03-13
Abatement Due Date 2014-03-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress. a) For the jobsite at 3300 Bonita Beach Rd., Bonita Springs, FL 33716, as observed on or about 02/25/2014, Karr Brothers Drywall, Inc. was hired to perfom stucco work and was the controlling contractor for stucco work. Employees of Karr Brothers Drywall Inc. and another subcontractor were exposed to fall hazards from accessing the scafolding without a ladder. Employees were observed climbing the cross braces and the scaffolding frame of the tubular welded scaffolding that was in place on site.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
2093798208 2020-07-31 0455 PPP 3550 WORK DR UNIT B9, FORT MYERS, FL, 33916-7514
Loan Status Date 2021-05-19
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 297912
Loan Approval Amount (current) 297912
Undisbursed Amount 0
Franchise Name -
Lender Location ID 9551
Servicing Lender Name Bank of America, National Association
Servicing Lender Address 100 N Tryon St, Ste 170, CHARLOTTE, NC, 28202-4024
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address FORT MYERS, LEE, FL, 33916-7514
Project Congressional District FL-19
Number of Employees 60
NAICS code 238310
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 9551
Originating Lender Name Bank of America, National Association
Originating Lender Address CHARLOTTE, NC
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 299805.58
Forgiveness Paid Date 2021-03-31

Date of last update: 01 Apr 2025

Sources: Florida Department of State