Search icon

GIL CLOUTIER ROOFS, ROOMS, RENOVATIONS & REPAIRS, INC. - Florida Company Profile

Company Details

Entity Name: GIL CLOUTIER ROOFS, ROOMS, RENOVATIONS & REPAIRS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GIL CLOUTIER ROOFS, ROOMS, RENOVATIONS & REPAIRS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 Apr 2011 (14 years ago)
Date of dissolution: 25 Sep 2015 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (9 years ago)
Document Number: P11000032535
FEI/EIN Number 451439934

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3143 WALLER STREET, JACKSONVILLE, FL, 32254
Mail Address: 3143 WALLER STREET, JACKSONVILLE, FL, 32254
ZIP code: 32254
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CLOUTIER GILBERT N President 3143 WALLER STREET, JACKSONVILLE, FL, 32254
CLOUTIER GILBERT N Agent 3143 WALLER STREET, JACKSONVILLE, FL, 32254

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J15000901435 LAPSED 14-269-D1 LEON 2015-07-08 2020-09-22 $62,438.98 DFS DIVISION OF WORKERS COMPENSATION, 200 EAST GAINES STREET, TALLAHASSEE, FL 32399-4228
J14000799949 LAPSED 2014 CA 003376 MA DUVAL COUNTY CIVIL 2014-07-14 2019-08-05 $48,874.06 AMERICAN BUILDERS & CONTRACTORS SUPPLY CO., INC., 800 NW 65TH STREET, FORT LAUDERDALE, FL 33309

Documents

Name Date
ANNUAL REPORT 2014-03-20
ANNUAL REPORT 2013-01-28
ANNUAL REPORT 2012-05-23
Domestic Profit 2011-04-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339589178 0419700 2014-02-14 10570 CRYSTAL SPRINGS RD., JACKSONVILLE, FL, 32221
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-02-14
Emphasis L: FALL, P: FALL
Case Closed 2015-04-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-03-03
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-03-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about February 14, 2014, on the roof, employees using pneumatic air nailers while installing roofing components were not using eye protection, exposing themselves to eye injuries.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260416 A01
Issuance Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 2400.0
Final Order 2014-03-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a. On or about February 14, 2014, on the 7:12 pitch roof, employees were conducting roofing operations within inches of a 200 ampres drop-down power line, exposing themselves to an electrical hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 5600.0
Final Order 2014-03-27
Nr Instances 3
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line Gil Cloutier Roofs, Rooms, Renovations & Repairs, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 315482521, citation number 01, item number 001 and was affirmed as a final order on January 17, 2012, with respect to a workplace located at 808 Tortoise Way, Jacksonville, Florida, 32218. 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about February 14, 2014, on the 7:12 pitch roof, employees performing roofing operations were not protected from a 13 feet 8-inch fall hazard from the gable by the use of a fall protection system. b. On or about February 14, 2014, on the 7:12 pitch roof, employees performing roofing operations were not protected from an 8 feet fall hazard on the north side of the house by the use of a fall protection system. c. On or about February 14, 2014, on the 7:12 pitch roof, employees performing roofing operations were not protected from a 10 feet fall hazard on the east and south side of the house by the use of a fall protection system.
Citation ID 03001
Citaton Type Other
Standard Cited 19260050 D01
Issuance Date 2014-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-03-27
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: a. On or about February 14, 2014, the employer did not provide first aid supplies for employees.
315482521 0419700 2011-12-09 808 TORTOISE WAY, JACKSONVILLE, FL, 32218
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2011-12-09
Emphasis L: FALL, S: FALL FROM HEIGHT, S: RESIDENTIAL CONSTR
Case Closed 2016-01-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2011-12-20
Abatement Due Date 2011-12-23
Current Penalty 1530.0
Initial Penalty 2550.0
Nr Instances 1
Nr Exposed 4
Gravity 05

Date of last update: 02 Mar 2025