Search icon

SAMG BUILDERS INC.

Company Details

Entity Name: SAMG BUILDERS INC.
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 25 Mar 2011 (14 years ago)
Date of dissolution: 05 Apr 2017 (8 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 05 Apr 2017 (8 years ago)
Document Number: P11000029881
FEI/EIN Number 45-1205156
Address: 1106 W. Oak St., Suite A, Kissimmee, FL 34741
Mail Address: 1106 W. Oak St., Suite A, Kissimmee, FL 34741
ZIP code: 34741
County: Osceola
Place of Formation: FLORIDA

Agent

Name Role Address
MILLA, SANTIAGO A Agent 1351 DUNBARTON CT, KISSIMMEE, FL 34758

President

Name Role Address
MILLA, SANTIAGO A President 1351 DUNBARTON CT, KISSIMMEE, FL 34758

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2017-04-05 No data No data
CHANGE OF PRINCIPAL ADDRESS 2014-01-10 1106 W. Oak St., Suite A, Kissimmee, FL 34741 No data
CHANGE OF MAILING ADDRESS 2014-01-10 1106 W. Oak St., Suite A, Kissimmee, FL 34741 No data

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J13000609165 TERMINATED 1000000400692 BROWARD 2013-03-18 2033-03-27 $ 330.00 STATE OF FLORIDA, DEPARTMENT OF REVENUE, CORAL SPRINGS SERVICE CENTER, 3301 N UNIVERSITY DR STE 200, CORAL SPRINGS FL330654149
J13000375395 TERMINATED 1000000400699 BROWARD 2013-02-01 2033-02-13 $ 330.00 STATE OF FLORIDA, DEPARTMENT OF REVENUE, CORAL SPRINGS SERVICE CENTER, 3301 N UNIVERSITY DR STE 200, CORAL SPRINGS FL330654149

Documents

Name Date
ANNUAL REPORT 2016-01-12
ANNUAL REPORT 2015-03-25
ANNUAL REPORT 2014-01-10
ANNUAL REPORT 2013-01-17
ANNUAL REPORT 2012-01-16
Domestic Profit 2011-03-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341340925 0419700 2016-03-22 118 FISHERMANS COVE DR MODEL #2, EDGEWATER, FL, 32141
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-03-22
Emphasis L: FALL, P: FALL
Case Closed 2018-09-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2016-04-05
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-05-02
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) On or about March 22, 2016 CHSO observed two employees on the rooftop cutting and securing plywood sheathing to the roof trusses, using pneumatic nailers and portable electric saws and were not protected from physical impact injuries to the eyes because they were not wearing any eye protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2016-04-05
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-05-02
Nr Instances 2
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about March 22, 2016 four employees were exposed to electrical shock hazards while operating portable electric 7-1/4" power saws because the flexible extension cords they were using to energize the saws did not have a continuous path to ground, because the ground pin contact had been broken off or removed.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-04-05
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-05-02
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 22, 2016, two employees were nailing new roof sheathing to roof trusses and were not protected from falls in excess of 12 feet to the concrete slab below because they were not protected by any means of personal fall protection harnesses, guardrails, or safety nets.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-04-05
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2016-05-02
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On March 22, 2016 two employees were working on the roof top and were not protected from falling off the roof to the ground below while getting on or off of the ladder because the ladder was not properly positioned to allow for safe access to the roof surface.
Citation ID 02001
Citaton Type Other
Standard Cited 19040040 A
Issuance Date 2016-04-05
Abatement Due Date 2016-05-20
Current Penalty 0.0
Initial Penalty 400.0
Final Order 2016-05-02
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Imminent Danger
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a). On March 22, 2016 CSHO requested copies of the companies OSHA 300 and 301 logs for review. On March 25, 2016 during a telephonic closing conference with the employer, CSHO again requested the OSHA logs be emailed or faxed to CSHO for review. On or about March 30, 2016, CSHO received the companies OSHA 300 logs only.
Citation ID 02002
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2016-04-05
Abatement Due Date 2016-05-20
Current Penalty 0.0
Initial Penalty 400.0
Final Order 2016-05-02
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) On or about March 22, 2016 the employer did not provide a training program for each employee who might be exposed to fall hazards. CSHO observed 2 employees working on a steep slope 6:12 pitch, residential roof without any means of personal fall protection, guard rails or safety nets.

Date of last update: 23 Feb 2025

Sources: Florida Department of State