Search icon

DESTIN CITY INC

Company Details

Entity Name: DESTIN CITY INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 24 Feb 2011 (14 years ago)
Date of dissolution: 27 Sep 2013 (11 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2013 (11 years ago)
Document Number: P11000019804
FEI/EIN Number N/A
Address: 4070 DANCING CLOUD, 192, DESTIN, FL 32541
Mail Address: 4070 DANCING CLOUD, 192, DESTIN, FL 32541
ZIP code: 32541
County: Okaloosa
Place of Formation: FLORIDA

Agent

Name Role Address
XAVIER, EVANDRO Agent 4070 DANCING CLOUD, 192, DESTIN, FL 32541

President

Name Role Address
XAVIER, EVANDRO President 4070 DANCING CLOUD 192, DESTIN, FL 32541

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 No data No data

Documents

Name Date
ANNUAL REPORT 2012-02-21
Domestic Profit 2011-02-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337145429 0419700 2012-10-31 579 SANDGRASS BOULEVARD LOT 23, SANTA ROSA BEACH, FL, 32459
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-10-31
Emphasis P: EISAOF, L: FALL, L: EISAOF
Case Closed 2018-02-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-01-30
Current Penalty 2640.0
Initial Penalty 2640.0
Final Order 2013-04-03
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 31, 2012, an employee performing framing operations was not protected from a 9 feet 8-inch interior fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2013-01-30
Current Penalty 1760.0
Initial Penalty 1760.0
Final Order 2013-04-03
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a. On or about October 31, 2012, an employee performing framing operations used the top step of a 6-foot A-frame step ladder to access the top plate, exposing himself to a fall hazard.
337131809 0419700 2012-10-30 61 BEAR GRASS WAY, SANTA ROSA BEACH, FL, 32459
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-10-30
Emphasis L: FALL
Case Closed 2018-02-01

Related Activity

Type Inspection
Activity Nr 714541
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-02-12
Current Penalty 2640.0
Initial Penalty 2640.0
Final Order 2013-04-03
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 30, 2012, on a low pitch roof, in the front of the structure, an employee performing framing operations was not protected from a 12 feet 4-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system, or any alternate fall protection. b. On or about October 30, 2012, on a low pitch roof, on the side of the structure, an employee performing framing operations was not protected from a 12 feet 8-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system, or any alternate fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2013-02-12
Current Penalty 2640.0
Initial Penalty 2640.0
Final Order 2013-04-03
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a. On or about October 30, 2012, the stairway system used to access the 2nd level did not have a stairrail system on an unprotected side, exposing employees to a fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2013-02-12
Current Penalty 2640.0
Initial Penalty 2640.0
Final Order 2013-04-03
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems: a. On or about October 30, 2012, the stairway landing between the 1st and 2nd floors did not have any guardrails, exposing employees to a fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260025 A
Issuance Date 2013-02-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-04-03
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a. On or about October 30, 2012, inside and around the structure work areas were not kept clear from debris and trash, exposing employees to a tripping hazard.
336718994 0419700 2012-10-05 53 COMPASS POINT WAY LOT 42, WATERSOUND, FL, 32413
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-10-05
Emphasis L: FALL, L: EISAOF
Case Closed 2018-02-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2012-10-16
Current Penalty 1020.0
Initial Penalty 1020.0
Final Order 2012-11-14
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a. On or about October 5, 2012, an employee using a Hitachi NR83A2 pneumatic air nail gun did not have safety glasses, exposing himself to being hit by nails or flying debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-10-16
Current Penalty 2040.0
Initial Penalty 2040.0
Final Order 2012-11-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about October 5, 2012, an employee performing siding operations was not protected from a 14 foot fall hazard by use of a guardrail system, safety net system, or personal fall arrest system.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2012-10-16
Current Penalty 1020.0
Initial Penalty 1020.0
Final Order 2012-11-14
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 5, 2012, on a 12:12 pitch roof, an employee performing siding operations was not protected from an 8 feet 6-inch fall hazard by use of a guardrail system, safety net syste, personal fall arrest system or any alternative fall protection.