Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-12-10
|
Case Closed |
2021-12-01
|
Related Activity
Type |
Referral |
Activity Nr |
1526247 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260059 |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
2775.6 |
Initial Penalty |
4626.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.59: The employer had not developed a written hazard communication program in accordance with 29 CFR 1910.1200 as incorporated by reference: On or about December 10, 2019, at 16611 Sunset Drive Weston, FL 33326 jobsite, the employer did not develop and implement a written hazard communication program for employees using hazardous chemicals, including, but not limited to Portland Cement, exposing employees to a hazardous chemical burns. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261153 I01 |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(i)(1): The employer did not include respirable crystalline silica in the program established to comply with the hazard communication standard (HCS) (29 CFR 1910.1200): On or about December 10th, 2019, at 16611 Sunset Drive Weston, FL 33326, the employer did not include the exposure to silica in its hazard communication program while employees were paving driveways with material that contained up to five (5%) percent silica quartz. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261153 C01 |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
2775.6 |
Initial Penalty |
4626.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section. On or about December 10th, 2019, at jobsite located at 16611 Sunset Drive Weston, FL 33326, the employer did not develop and implement engineering controls for employees holding a water hose instead of integrating a water connected directly to the saw as required in Table 1 while employees were paving driveways with material that contained up to five (5%) percent silica quartz. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261153 D02 I |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: On or about December 10th, 2019, at jobsite located at 16611 Sunset Drive Weston, FL 33326, the employer did not assess the exposure to silica for employees performing stucco work and exposed to material that contained up to five (5%) percent silica quartz. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19261153 G01 |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan that contained at least the elements of paragraph(s) 1926.1153(g)(1)(I) through (iv): On or about December 10th, 2019, at jobsite located at 16611 Sunset Drive Weston, FL 33326, the employer did not develop and implement a written exposure control plan for silica while employees performed stucco work with material that contained up to five (5%) percent silica quartz. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100134 C02 II |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
2775.6 |
Initial Penalty |
4626.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (Construction Reference 1926.103) On or about December 10th, 2019, at jobsite location at 16611 Sunset Drive Weston, FL 33326, the employer did not establish a written respiratory protection program for silica while employees performed stucco work with material that contained up to five (5%) percent silica quartz. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100134 K06 |
Issuance Date |
2020-05-04 |
Abatement Due Date |
2020-05-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-05-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (Construction Reference 1926.103) On or about December 10th, 2019, at jobsite location at 16611 Sunset Drive Weston, FL 33326, the employer did not provide the information contained in Appendix D of 29 CFR 1910.134, for employees who use respirators while performed paving work with material that contained up to five (5%) percent silica quartz. |
|
|