Search icon

ALEX VALERIO'S CARPENTRY, INC. - Florida Company Profile

Company Details

Entity Name: ALEX VALERIO'S CARPENTRY, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ALEX VALERIO'S CARPENTRY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 03 Feb 2011 (14 years ago)
Date of dissolution: 23 Sep 2016 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (9 years ago)
Document Number: P11000012379
FEI/EIN Number 800679995

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 806 29TH STREET COURT E., BRADENTON, FL, 34208, US
Mail Address: 806 29TH STREET COURT EAST, BRADENTON, FL, 34208, US
ZIP code: 34208
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
VALERIO ALEX President 805 29TH ST CT E, BRADENTON, FL, 34208
VALERIO ALEX Agent 805 29TH ST CT E, BRADENTON, FL, 34208

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -
REGISTERED AGENT NAME CHANGED 2014-01-03 VALERIO, ALEX -
REGISTERED AGENT ADDRESS CHANGED 2014-01-03 805 29TH ST CT E, BRADENTON, FL 34208 -
CHANGE OF PRINCIPAL ADDRESS 2013-04-24 806 29TH STREET COURT E., BRADENTON, FL 34208 -
CHANGE OF MAILING ADDRESS 2013-04-24 806 29TH STREET COURT E., BRADENTON, FL 34208 -
REINSTATEMENT 2013-01-15 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2012-09-28 - -

Documents

Name Date
ANNUAL REPORT 2015-01-13
AMENDED ANNUAL REPORT 2014-03-18
ANNUAL REPORT 2014-01-03
AMENDED ANNUAL REPORT 2013-04-24
REINSTATEMENT 2013-01-15
Domestic Profit 2011-02-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340954791 0420600 2015-09-30 701 EAST BAY DR, LARGO, FL, 33770
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-09-30
Emphasis L: FALL, P: FALL
Case Closed 2019-12-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-10-26
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-12-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a. At the northeast end of the two story apartment building, fall protection was not provided for employees working on the 4/12 pitch roof, exposing employees to a fall hazard of approximately 16 foot on or about 9/30/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-10-26
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-12-16
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a. On the northeast side of the apartment building, the portable extension ladder used to access the rooftop was extended one rung above the upper landing of the roof, exposing employees to a 16 foot fall hazard.on or about 9/30/2015.
340135102 0420600 2014-12-11 203 17TH STREET, BRADENTON BEACH, FL, 34217
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-12-11
Emphasis L: FALL, P: FALL
Case Closed 2017-11-16

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260404 B01 III C
Issuance Date 2015-03-04
Current Penalty 1540.0
Initial Penalty 3080.0
Final Order 2015-03-20
Nr Instances 1
Nr Exposed 9
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(iii)(C): A cord set, attachment cap, plug or receptacle of cord sets, or any equipment connected by cord and plug, that was found damaged or defective was used before it was repaired. a) For employees working at 203 17th Street in Bradenton Beach, as observed on or about December 11, 2014. Employees were using an extension cord to supply power to electrical tools that showed visible damage such as outer insulation missing and the conducts were exposed.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2015-03-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-20
Nr Instances 1
Nr Exposed 9
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) For employees working at 203 17th Street in Bradenton Beach, as observed on or about December 11, 2014. Employees were using an extension cord to supply power to electrical tools. Extension cord in use did not have the ground prong so the path to ground was not permanent and continuous.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-03-04
Current Penalty 1540.0
Initial Penalty 3080.0
Final Order 2015-03-20
Nr Instances 1
Nr Exposed 9
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) For employees working at 203 17th Street in Bradenton Beach, as observed on or about December 11, 2014. Employees were using an extension ladder to access the third floor balcony from the second floor balcony that did not have the side rails extended a minimum of 3 feet above the upper landing surface. The ladder side rails only extended approximately 16 inches above the upper landing surface.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2015-03-04
Abatement Due Date 2015-03-16
Current Penalty 3080.0
Initial Penalty 6160.0
Final Order 2015-03-20
Nr Instances 3
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at 203 17th Street in Bradenton Beach, as observed on or about December 11, 2014. Employees were installing framing lumber and sheathing on the third floor roof of a residential home above 6 feet without the use of any fall protection. The roof pitch was 8:12. Employees were exposed to a fall hazard of over 23 feet. b) For employees working at 203 17th Street in Bradenton Beach, as observed on or about December 11, 2014. Employees were accessing the third floor balcony from the second floor balcony of a residential home. the 2nd floor balcony had unprotected sides above 6 feet without the use of a fall protection system in place. Employees were exposed to a fall hazard of approximately 14 feet. Alex Valerio's Carpentry, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 912271, citation number 01, item number 001 and was affirmed as a final order on 9 September, 2013, with respect to a workplace located at 6713 Congress Street., New Port Richey, Florida.
339446171 0418800 2013-10-25 11181 MONTECARLO BLVD, NAPLES, FL, 34104
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2013-10-25
Emphasis L: FALL
Case Closed 2018-10-31

Related Activity

Type Referral
Activity Nr 857145
Safety Yes
Type Inspection
Activity Nr 944090
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2014-01-24
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: On or about 10/25/2013, at the above addressed job site, the employer did not provide an employee with eye protection exposing the employee to a struck-by hazard of nails while using a nailgun to install plywood onto the trusses.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-01-24
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-02-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 10/25/2013, at the above addressed job site, an employee was installing plywood on the trusses of a residential home and was not protected from fall hazards of approximately 13 feet above ground level.
339122715 0420600 2013-06-18 6713 CONGRESS ST., NEW PORT RICHEY, FL, 34653
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-06-18
Emphasis L: FALL, P: FALL
Case Closed 2014-06-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-06-28
Current Penalty 1480.0
Initial Penalty 2800.0
Final Order 2013-09-13
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about 06-18-2013 at the job site, while working on unprotected block wall the use of fall protection equipment was not required exposing employees to a 65 ft. fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 B01
Issuance Date 2013-06-28
Abatement Due Date 2013-07-18
Current Penalty 520.0
Initial Penalty 1200.0
Final Order 2013-09-13
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about 06-18-2013 at the site, no certification of training was provided that verified employees had received training to recognize fall hazards and procedures to follow or minimize fall hazards.