Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2020-05-21
|
Case Closed |
2020-08-18
|
Related Activity
Type |
Referral |
Activity Nr |
1532414 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1459473 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100107 B02 |
Issuance Date |
2020-06-03 |
Abatement Due Date |
2020-06-29 |
Current Penalty |
1041.0 |
Initial Penalty |
1735.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(2): The interior surfaces of spray booths were not smooth and continuous without edges and otherwise designed to prevent pocketing of residues. On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop booths, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer failed to maintain the interior surfaces of spray booths smooth and continuous without edges and otherwise designed to prevent pocketing of residues, exposing employees fire hazards. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 I |
Issuance Date |
2020-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(i): The spraying operations was not designed, installed or maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop booths #3 and 4, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer failed to maintain the average air velocity over the open face of the booths at no less than 100 linear feet per minute, exposing employees to hazardous chemicals and resulting in health hazards such as, but not limited to acute and chronic respiratory injury and illness. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 IV |
Issuance Date |
2020-06-03 |
Abatement Due Date |
2020-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers. On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop booths, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer failed to protect the upstream side of filters with approved automatic sprinklers, exposing employees to fire hazards. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2020-06-03 |
Current Penalty |
1041.0 |
Initial Penalty |
1735.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer required employees to use tight fitting, half faced mask respirators, during cabinet finishing operations, without a written respiratory protection program, exposing these employees to health hazards such as, but not limited to acute and chronic respiratory injury and illness. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2020-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer required employees to use tight fitting, half faced mask respirators, during cabinet finishing operations, without first having these employees complete a medical evaluation, exposing the employees to health hazards such as, but limited to acute and chronic respiratory injury and illness. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2020-06-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer required employees to use tight fitting, half faced mask respirators, during cabinet finishing operations, without first having these employees complete a fit test, exposing the employees to health hazards such as, but limited to acute and chronic respiratory injury and illness. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100134 K |
Issuance Date |
2020-06-03 |
Abatement Due Date |
2020-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer required employees to use tight fitting, half faced mask respirators, during cabinet finishing operations, without training prior to an employee's use of a respirator, exposing these employees to health hazards such as, but limited to acute and chronic respiratory injury and illness. |
|
Citation ID |
01002E |
Citaton Type |
Serious |
Standard Cited |
19100134 H02 I |
Issuance Date |
2020-06-03 |
Abatement Due Date |
2020-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer required employees to use tight fitting, half faced mask respirators, during cabinet finishing operations, and did not ensure storage/package of respirators, exposing these employees to health hazards such as, but not limited to acute and chronic respiratory injury and illness. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100141 G04 |
Issuance Date |
2020-06-03 |
Abatement Due Date |
2020-06-29 |
Current Penalty |
1041.0 |
Initial Penalty |
1735.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(g)(4): Employer did not store food or beverages away from toilet rooms or areas exposed to toxic materials: On or about January 28, 2020, and at times prior, across from paint storage #1 (by bench next to microwave and refrigerator), of Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer failed to store food and beverages exposed to toxic materials. Numerous unlabeled Gatorade bottles containing paint were mixed with employees' beverages. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2020-06-03 |
Current Penalty |
195.0 |
Initial Penalty |
325.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer required employees to store, transport and use hazardous chemicals such as, but not limited to lacquers and paints; exposing these employees to health hazards such as acute and chronic respiratory injury and illness. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 F06 |
Issuance Date |
2020-06-03 |
Abatement Due Date |
2020-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: On or about January 28, 2020, and at times prior, throughout Florida Cabinet Finishing, Inc.'s paint shop, located at 3301 McLemore Drive, Pensacola, Florida 32514, the employer did not label containers that were prior Gatorade bottles and were later used to store paint, exposing employees to contact with toxic substances by ingestion through digestive track. |
|
|