Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-06-19
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2014-07-22
|
Related Activity
Type |
Inspection |
Activity Nr |
963541 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19100303 F02 |
Issuance Date |
2014-06-20 |
Abatement Due Date |
2014-07-10 |
Current Penalty |
80.0 |
Initial Penalty |
80.0 |
Final Order |
2014-07-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) For the Printer's Edge facility at 6229 Edgewater Drive Suite 400, Orlando, FL 32810, as observed on or about 03/13/2014, a breaker panel near the Kluge Foil Stamping machines, controlling power to lighting and/or other devices, did not have all breakers labeled. M&W Equity Partners, Inc. dba The Printers Edge was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1910.303(f)(2)), which was contained in OSHA inspection number 963541, citation number 2, item number 1, and was affirmed as a final order on 04/24/2014 with respect to a workplace located at 6229 Edgewater Dr. Suite 400, Orlando, FL 32810. |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-03-13
|
Emphasis |
N: AMPUTATE, P: AMPUTATE, L: EISAX, L: EISAOF
|
Case Closed |
2014-07-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2014-03-31 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) For the Printer's Edge facility at 6229 Edgewater Dr. Suite 400, Orlando, FL 32810, as observed on or about 03/13/2014, employees used an abrasive wheel bench grinder that was missing a tongue guard. Gaps of 0.5 and 1.5 inches were measured between the abrasive wheel periphery and the peripheral safety guard. Employees were exposed to shrapnel hazards in event of a wheel shattering. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-04-24 |
Current Penalty |
1440.0 |
Initial Penalty |
2400.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) For The Printer's Edge facility at 6229 Edgewater Dr. Suite 400, Orlando, FL 32810, as observed on or about 03/13/2014, employees working at the Kluge Foil Stamping machines were exposed to potential amputation hazards from an unguarded belt and pulley that transmitted power from the motor drive shaft to the machines. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-04-10 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) For The Printers Edge facility at 6229 Edgewater Dr. Suite 400, Orlando, FL 32810, as observed on or about 03/13/2014, employees used compressed air at pressures of up to 70 p.s.i. dead front pressure to clean off parts and equipment. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-04-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) For the Printers Edge facility at 6229 Edgewater Dr. Suite 400, Orlando, FL 32810, as observed on or about 03/13/2014: breaker panels near the Kluge Foil Stamping machines, controlling power to lighting, were not labeled. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-04-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) For the Printer's Edge facility at 6229 Edgewater Dr. Suite 400, Orlando, FL 32810, as observed on or about 03/13/2014, chemicals such as, but not limited to, printer inks and cleaners were used on site. No written hazardous communications program was in place for the facility. |
|
|