Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Emphasis |
L: FORKLIFT, N: CHROME6
|
Case Closed |
2015-09-02
|
Related Activity
Type |
Complaint |
Activity Nr |
891659 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 L |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: a) for employee at the shop located at 313 Seaboard Avenue Suite B Venice, (FL) operating a CATERPILLAR-LP GC25 forklift (Serial Number 4EM06882), as observed on or about 6/5/2014. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101026 D01 |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) for employee welding stainless steel surfaces at the shop located at 313 Seaboard Avenue Suite B, Venice (FL), on or about 6/5/2014. The employer did not make the exposure determination in accordance with either paragraph (d)(2), the scheduled monitoring option, or paragraph (d)(3), the performance-oriented option. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) at the fabrication shop located at 313 Seaboard Avenue Suite B, Venice (FL) as observed on or about 6/5/2014. For compress gases included but not limited to Oxygen, Acetylene, Propane, Argon 100% and Argon 75%/CO2 2.5%, fluids such as but not limited to Parathern HE, solvents such as but not limited to Xylene and Naphtha and stainless steel such as but not limited to 316L and Zeron 100 handled by employees involved in the water evaporator fabrication and testing. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a) at the fabrication shop located at 313 Seaboard Avenue Suite B, Venice (FL) as observed on or about 6/5/2014. For compress gases included but not limited to Oxygen, Acetylene, Propane, Argon 100% and Argon 75%/CO2 2.5%, fluids such as but not limited to Parathern HE, solvents such as but not limited to Xylene and Naphtha and stainless steel such as but not limited to 316L and Zeron 100 involved in the water evaporator fabrication and testing. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) at the fabrication shop located at 313 Seaboard Avenue Suite B, Venice (FL) as observed on or about 6/5/2014. For compress gases included but not limited to Oxygen, Acetylene, Propane, Argon 100% and Argon 75%/CO2 2.5%, fluids such as but not limited to Parathern HE, solvents such as but not limited to Xylene and Naphtha and stainless steel such as but not limited to 316L and Zeron 100 handled by employees involved in the water evaporator fabrication and testing. |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19101200 H03 IV |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information: a) at the fabrication shop located at 313 Seaboard Avenue Suite B, Venice (FL) as observed on or about 6/5/2014. For compress gases included but not limited to Oxygen, Acetylene, Propane, Argon 100% and Argon 75%/CO2 2.5%, fluids such as but not limited to Parathern HE, solvents such as but not limited to Xylene and Naphtha and stainless steel such as but not limited to 316L and Zeron 100 handled by employees involved in the water evaporator fabrication and testing. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) for the employee at the shop located at 313 Seaboard Avenue Suite B, Venice (FL) voluntarily using a Miller LPR-100 Half Mask Respirator ML00894 while welding stainless steel surfaces, as observed on or about 6/5/2014. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) for the employee at the shop located at 313 Seaboard Avenue Suite B, Venice (FL) voluntarily using a Miller LPR-100 Half Mask Respirator ML00894 while welding stainless steel surfaces, as observed on or about 6/5/2014. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2014-07-01 |
Abatement Due Date |
2014-07-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) in that a fire extinguisher located in the fabrication shop area located at 313 Seaboard Avenue Suite B Venice, (FL) was obstructed by welding materials, as observed on or about 6/5/2014. |
|
|