Entity Name: RICK ONEAL STUCCO & STONE INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

RICK ONEAL STUCCO & STONE INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 23 Nov 2010 (14 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 10 Jan 2020 (5 years ago)
Document Number: P10000095856
FEI/EIN Number 274060151

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 10706 MAGNOLIA DR, THONOTOSASSA, FL, 33592, US
Mail Address: 10706 MAGNOLIA DR, THONOTOSASSA, FL, 33592, US
ZIP code: 33592
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ONEAL RICKY M President 10706 MAGNOLIA DR, THONOTOSASSA, FL, 33592
ONEAL RICKY M Agent 10706 MAGNOLIA DR, THONOTOSASSA, FL, 33592

Events

Event Type Filed Date Value Description
REINSTATEMENT 2020-01-10 - -
REGISTERED AGENT NAME CHANGED 2020-01-10 ONEAL, RICKY M -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
ANNUAL REPORT 2024-04-23
ANNUAL REPORT 2023-04-21
ANNUAL REPORT 2022-05-01
ANNUAL REPORT 2021-04-30
REINSTATEMENT 2020-01-10
ANNUAL REPORT 2018-03-21
ANNUAL REPORT 2017-03-17
ANNUAL REPORT 2016-04-04
ANNUAL REPORT 2015-02-22
ANNUAL REPORT 2014-04-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338021900 0420600 2012-12-27 3520 N. PERRY AVE, TAMPA, FL, 33618
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-12-27
Emphasis N: SILICA, L: SILICA, L: FALL, P: FALL
Case Closed 2016-09-29

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-01-28
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-02-22
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no a. At the site, employees applying stucco were exposed a fall of 19.5 feet from a scaffold that was not fully planked . On or about 12/27/12.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-01-28
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2013-02-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. At the site employees were exposed to a fall of 19.5 feet, in that, scaffolds members were used as a means of access and egress no ladder was provided. On or about 12/
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01 V
Issuance Date 2013-01-28
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2013-02-22
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(v): Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway. At the site, employees were exposed to a fall of 19.5 feet in that, while applying stucco from the scaffold walkway there was no guard rail system. On or about 12/27/12
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2013-01-28
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-02-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement. a. At the site, employees applying stucco 19.5 feet above the ground below were exposed to a struck by hazard, in that, the scaffold they were working from was sinking into the ground causing the scaffolding to lean while in use. On or about 12/27/12.