341806321
|
0418800
|
2016-09-29
|
15074 PARK OF COMMERCE BOULEVARD SUITE 13, JUPITER, FL, 33478
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-09-29
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2017-03-27
|
Related Activity
Type |
Complaint |
Activity Nr |
1140582 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2016-12-21 |
Abatement Due Date |
2017-02-09 |
Current Penalty |
0.0 |
Initial Penalty |
2138.0 |
Final Order |
2017-01-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user On or about 9/29/16, at the above address jobsite, employees who wear a tight fitting respirator were not provided with a medical evaluation. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100146 C01 |
Issuance Date |
2016-12-21 |
Abatement Due Date |
2017-01-19 |
Current Penalty |
400.0 |
Initial Penalty |
2138.0 |
Final Order |
2017-01-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: On or about 9/29/2016, at the above address jobsite, employees would enter mixing tanks without having the space evaluated to determine if it was a permit-required confined space. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2016-12-21 |
Abatement Due Date |
2017-01-19 |
Current Penalty |
2800.0 |
Initial Penalty |
3563.0 |
Final Order |
2017-01-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: On or about 10/13/2016 at the above addressed jobsite, employees were exposed to the hazard of working with a drill press (model 0016, SN:0129095) that was not guarded at the point of operation. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2016-12-21 |
Abatement Due Date |
2017-02-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-01-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about 9/29/16, at the above address jobsite, employees who wear a tight fitting respirator were not given the appendix D of the respirator standard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2016-12-21 |
Abatement Due Date |
2017-02-09 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Final Order |
2017-01-17 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Instances: 1. On or about 10/13/ 2016, at the above addressed jobsite, the employer did not provide an eye wash for employees exposed to corrosive chemicals such as but not limited to phosphoric acid (70% solution) in the quality control laboratory. 2. On or about 10/13/ 2016, at the above addressed jobsite, the employer did not provide an eye wash for employees exposed to corrosive chemicals such as but not limited to phosphoric acid (70% solution) in the research and development laboratory. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2016-12-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-01-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about 09/29/016, at the above address jobsite, the employer did not evaluate the employees operating forklifts at the facility within 3 years from their last evalaution. |
|
|
339172975
|
0418800
|
2013-06-27
|
15074 PARK OF COMMERCE BOULEVARD SUITE 13, JUPITER, FL, 33478
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-06-27
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2013-06-28
|
Related Activity
Type |
Complaint |
Activity Nr |
825041 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
852930 |
Safety |
Yes |
|
|
336727185
|
0418800
|
2012-10-05
|
15074 PARK OF COMMERCE BOULEVARD SUITE 13, JUPITER, FL, 33478
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-10-05
|
Case Closed |
2017-03-29
|
Related Activity
Type |
Referral |
Activity Nr |
592950 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19100134 C01 |
Issuance Date |
2012-12-31 |
Abatement Due Date |
2013-01-28 |
Current Penalty |
0.0 |
Initial Penalty |
80.0 |
Contest Date |
2013-04-25 |
Final Order |
2013-09-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about 11/08/12, In the Formulation Area, the employer did not have a written respiratory protection plan, to address the use of the 3M half face air purifying respirator by the employee during the manufacturing of fertilizers. Biochem Manufacturing Inc., was previously cited for a violation of this Occupational and Safety Standard 29 CFR 1910.134(c)(1), which was contained in OSHA inspection number 513998, Citation 1 Item 1 and was affirmed as a final order on September 14th 2012, with respect to the workplace located at 15074 park of Commerce Boulevard, Jupiter, FL 33478. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-12-31 |
Abatement Due Date |
2013-01-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-04-25 |
Final Order |
2013-09-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about 11/08/12, The employer did not develop and implement a written a hazard communication program to address the hazards associated with chemicals such as but not limited to urea, ammonia, potassium hydroxide and phosphorous acid. |
|
|
336631585
|
0418800
|
2012-10-01
|
15074 PARK OF COMMERCE BOULEVARD SUITE 13, JUPITER, FL, 33478
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-10-01
|
Emphasis |
L: FORKLIFT, L: EISAOF
|
Case Closed |
2013-01-25
|
Related Activity
Type |
Referral |
Activity Nr |
592950 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
586890 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A02 |
Issuance Date |
2012-11-20 |
Current Penalty |
480.0 |
Initial Penalty |
1200.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: In the warehouse production and packaging areas of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: The floors in the company warehouse production and packaging areas were not kept in a clean and dry condition being covered with chemicals and or water creating a slip and fall hazard, on or about October 1, 2012. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2012-11-20 |
Current Penalty |
640.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: The cord of a Relocatable Power Tap (RPT) being used by employees was cut and spliced to the end of an electrical extension cord and was not connected directly to a receptacle, on or about October 1, 2012. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 |
Issuance Date |
2012-11-20 |
Current Penalty |
640.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: An electrical junction box with an outlet and light switch did not have the cover in place exposing energized wiring, on or about October 1, 2012. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2012-11-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: An electrical junction box with an outlet and light switch did not have each unused opening effectively closed, on or about October 1, 2012. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2012-11-20 |
Current Penalty |
640.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: An electrical flexible extension cord powering a Relocatable Power Tap (RPT) was used as a substitute for fixed wiring of a structure, on or about October 1, 2012. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 II |
Issuance Date |
2012-11-20 |
Current Penalty |
640.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: An electrical flexible cord powering tools was not used in a continuous length where the cord was severed, attached to a Relocatable Power Tap (RPT), and covered with electrical tape, on or about October 1, 2012. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2012-11-20 |
Current Penalty |
640.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: A flexible cord supplying power to a Husky Pro Air Compressor was not connected to the fitting of the electrical box to provide it with strain relief, on or about October 1, 2012. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L06 |
Issuance Date |
2012-11-20 |
Abatement Due Date |
2012-12-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-12-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph: In the warehouse packaging area of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: The employer did not certify that each powered industrial truck operator had certification that included the name of the operator, the date of training, the date of evaluation, and the identity of the person performing the training or evaluation, on or about October 1, 2012. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|
335139986
|
0418800
|
2012-07-11
|
15074 PARK OF COMMERCE BOULEVARD SUITE 13, JUPITER, FL, 33478
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-07-11
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2012-09-12
|
Related Activity
Type |
Complaint |
Activity Nr |
428750 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2012-08-17 |
Abatement Due Date |
2012-08-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-12 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: In the warehouse of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: The employer did not establish and maintain a written respiratory protection program for employees using ? face respirators while working with chemicals including but not limited to Calcium Oxide and or Potassium Hydroxide, on or about July 11, 2012. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100178 L06 |
Issuance Date |
2012-08-17 |
Abatement Due Date |
2012-08-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-09-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l): In the warehouse of Biochem Manufacturing, Inc. located at 15074 Park of Commerce Boulevard in Jupiter, Florida: The employer did not certify that each powered industrial truck operator had received training and certification prior to allowing them to operate the powered industrial trucks, on or about July 11, 2012. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|