Entity Name: | TAVERA CONSULTING CORP. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
TAVERA CONSULTING CORP. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 01 Sep 2010 (15 years ago) |
Date of dissolution: | 28 Sep 2012 (13 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 28 Sep 2012 (13 years ago) |
Document Number: | P10000072053 |
FEI/EIN Number |
273402495
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 10781 SW 131ST AVE, MIAMI, FL, 33186 |
Mail Address: | 10781 SW 131ST AVE, MIAMI, FL, 33186 |
ZIP code: | 33186 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
TAVERA JORGE | Agent | 10781 SW 131ST AVE, MIAMI, FL, 33186 |
TAVERA JORGE | President | 10781 SW 131ST AVE, MIAMI, FL, 33186 |
TAVERA JORGE | Secretary | 10781 SW 131ST AVE, MIAMI, FL, 33186 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2012-09-28 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2011-04-20 |
Domestic Profit | 2010-09-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341727626 | 0418800 | 2016-08-23 | 3199 HALLANDALE BEACH BLVD., HALLANDALE BEACH, FL, 33009 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1127924 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1172731 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2017-02-22 |
Current Penalty | 5070.0 |
Initial Penalty | 5070.0 |
Final Order | 2017-08-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): On or about August 23, 2016, at the above addressed job site, employees were exposed to cave-in and engulfment hazards while installing drainage pipe and manhole boxes inside an excavation that exceeded 5 feet in depth without means of cave-in protection. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260651 K02 |
Issuance Date | 2017-02-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-08-18 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: On or about August 23, 2016, at the above addressed job site, employees were exposed to cave-in and engulfment hazards while installing drainage pipe and manhole boxes inside an excavation that exceeded 5 feet in depth without means of cave-in protection, and were not immediately removed from the excavation when the competent person was aware of the hazardous situation. |