Search icon

MENDOZA TILE, INC. - Florida Company Profile

Company Details

Entity Name: MENDOZA TILE, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

MENDOZA TILE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 10 Aug 2010 (15 years ago)
Date of dissolution: 22 Sep 2021 (3 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 22 Sep 2021 (3 years ago)
Document Number: P10000065240
FEI/EIN Number 273215878

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3940 NW 187TH Terrace, MIAMI GARDENS, FL, 33055, US
Mail Address: 3940 NW 187TH Terrace, MIAMI GARDENS, FL, 33055, US
ZIP code: 33055
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MENDOZA GUILLERMO President 3940 NW 187TH Terrace, MIAMI GARDENS, FL, 33055
Mendoza Magalli E Vice President 3940 NW 187TH Terrace, MIAMI GARDENS, FL, 33055
MENDOZA GUILLERMO Agent 3940 NW 187TH Terrace, MIAMI GARDENS, FL, 33055

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2021-09-22 - -
CHANGE OF PRINCIPAL ADDRESS 2019-02-26 3940 NW 187TH Terrace, MIAMI GARDENS, FL 33055 -
CHANGE OF MAILING ADDRESS 2019-02-26 3940 NW 187TH Terrace, MIAMI GARDENS, FL 33055 -
REGISTERED AGENT NAME CHANGED 2019-02-26 MENDOZA, GUILLERMO -
REGISTERED AGENT ADDRESS CHANGED 2019-02-26 3940 NW 187TH Terrace, MIAMI GARDENS, FL 33055 -

Documents

Name Date
VOLUNTARY DISSOLUTION 2021-09-22
ANNUAL REPORT 2021-02-07
ANNUAL REPORT 2020-04-05
ANNUAL REPORT 2019-02-26
ANNUAL REPORT 2018-03-16
ANNUAL REPORT 2017-03-27
ANNUAL REPORT 2016-03-03
ANNUAL REPORT 2015-03-26
ANNUAL REPORT 2014-03-26
AMENDED ANNUAL REPORT 2013-05-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340086388 0418800 2014-11-17 101 SW 36 COURT, MIAMI, FL, 33135
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2014-11-17
Emphasis L: FALL, P: FALL
Case Closed 2015-03-16

Related Activity

Type Inspection
Activity Nr 1008641
Safety Yes
Type Inspection
Activity Nr 1008635
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2015-01-29
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 11/17/2014, at the above addressed worksite, an employee cutting tile near the edge of a 3rd floor balcony did not have fall protection exposing him to a fall hazard of approximately 30-feet.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-01-29
Abatement Due Date 2015-02-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-24
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information will be met. On or about November 17, 2014, at the above addressed work site, the employer did not develop and maintain a written hazard communication program for employees using tile adhesive.