Search icon

D & C HOME SERVICES, CORP.

Company Details

Entity Name: D & C HOME SERVICES, CORP.
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 25 May 2010 (15 years ago)
Date of dissolution: 17 Apr 2017 (8 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 17 Apr 2017 (8 years ago)
Document Number: P10000045005
FEI/EIN Number 27-2678985
Address: 1238 NW 51st Way, Deerfield Beach, FL 33442
Mail Address: 1238 NW 51st Way, Deerfield Beach, FL 33442
ZIP code: 33442
County: Broward
Place of Formation: FLORIDA

Agent

Name Role Address
GIL, CLEUSAIR CESAR Agent 1238 NW 51st Way, Deerfield Beach, FL 33442

President

Name Role Address
GIL, CLEUSAIR CESAR President 1238 NW 51st Way, Deerfield Beach, FL 33442

Director

Name Role Address
GIL, CLEUSAIR CESAR Director 1238 NW 51st Way, Deerfield Beach, FL 33442

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2017-04-17 No data No data
CHANGE OF PRINCIPAL ADDRESS 2015-01-05 1238 NW 51st Way, Deerfield Beach, FL 33442 No data
CHANGE OF MAILING ADDRESS 2015-01-05 1238 NW 51st Way, Deerfield Beach, FL 33442 No data
REGISTERED AGENT ADDRESS CHANGED 2015-01-05 1238 NW 51st Way, Deerfield Beach, FL 33442 No data
REGISTERED AGENT NAME CHANGED 2012-04-09 GIL, CLEUSAIR CESAR No data

Documents

Name Date
Voluntary Dissolution 2017-04-17
ANNUAL REPORT 2016-01-14
ANNUAL REPORT 2015-01-05
ANNUAL REPORT 2014-03-25
ANNUAL REPORT 2013-02-18
ANNUAL REPORT 2012-04-09
ANNUAL REPORT 2011-03-19
ADDRESS CHANGE 2010-08-13
Domestic Profit 2010-05-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339362238 0418800 2013-05-03 80-83 ANDALUSIA AVE, CORAL GABLES, FL, 33134
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2013-05-03
Emphasis P: FALL, L: FALL
Case Closed 2015-02-17

Related Activity

Type Accident
Activity Nr 816100
Type Inspection
Activity Nr 903521
Safety Yes
Type Inspection
Activity Nr 905510
Safety Yes
Type Inspection
Activity Nr 905447
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-10-21
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-10-28
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about April 26nd, 2013, at the above addressed job site, an employee was not protected from falling from a second floor.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2013-10-21
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-10-28
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a. On or about April 25th, 2013, at the above addressed job site, employees were not protected from falling from a stairwell.