Search icon

CITY CONCRETE SYSTEMS, INC. - Florida Company Profile

Company Details

Entity Name: CITY CONCRETE SYSTEMS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CITY CONCRETE SYSTEMS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 20 May 2010 (15 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 26 Feb 2013 (12 years ago)
Document Number: P10000043695
FEI/EIN Number 272628373

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6220 TAYLOR ROAD, SUITE 101, NAPLES, FL, 34109
Mail Address: 6220 TAYLOR ROAD, SUITE 101, NAPLES, FL, 34109
ZIP code: 34109
County: Collier
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SHOUP PETER C Vice President 6220 TAYLOR ROAD #101, NAPLES, FL, 34109
Shoup Peter E President 6220 Taylor Road, Naples, FL, 34109
RICE ROGER B Agent 9010 STRADA STELL CT, NAPLES, FL, 34109

Events

Event Type Filed Date Value Description
PENDING REINSTATEMENT 2013-02-26 - -
REINSTATEMENT 2013-02-26 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2011-09-23 - -

Documents

Name Date
ANNUAL REPORT 2025-02-06
ANNUAL REPORT 2024-02-05
ANNUAL REPORT 2023-05-03
ANNUAL REPORT 2022-04-19
ANNUAL REPORT 2021-04-27
ANNUAL REPORT 2020-01-15
ANNUAL REPORT 2019-04-30
ANNUAL REPORT 2018-03-02
ANNUAL REPORT 2017-02-13
ANNUAL REPORT 2016-04-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343620431 0418800 2018-11-21 250 N PAMPANO BEACH BLVD, POMPANO BEACH, FL, 33060
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-11-21
Emphasis L: FALL, P: FALL
Case Closed 2019-12-17

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B01
Issuance Date 2019-01-24
Abatement Due Date 2019-02-12
Current Penalty 14586.6
Initial Penalty 20838.0
Final Order 2019-02-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about November 21, 2018, at 250 Pompano Beach Blvd, Pompano Beach Pompano Beach, FL, 33060, an employee performing framing work without the use of fall protection was exposed to a 35-ft. fall hazard. City Concrete Systems Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 982826, citation number 1, item number 1 and was affirmed as a final order on 09/25/2014, with respect to a workplace located at 8417 Sierra Meadows Blvd Naples, FL 34104.
339828261 0418800 2014-06-16 8417 SIERRA MEADOWS BLVD, NAPLES, FL, 34104
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-06-16
Emphasis N: CTARGET, P: FALL, L: FALL
Case Closed 2015-01-16

Related Activity

Type Inspection
Activity Nr 982812
Safety Yes
Type Inspection
Activity Nr 982902
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B01
Issuance Date 2014-08-29
Abatement Due Date 2014-09-11
Current Penalty 7000.0
Initial Penalty 13860.0
Final Order 2014-09-25
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. On or about June 16th, 2014, at the above addressed job site, employees were not protected from falling from a 12 feet high concrete block wall. REPEAT: COMMERCIAL CONCRETE SYSTEM LLC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(b)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 836584.015 , CITATION NUMBER 1, ITEM NUMBER 2, AND WAS AFFIRMED AS A FINAL ORDER ON MAY 9, 2013, WITH RESPECT TO A WORKPLACE LOCATED AT 400 GULF SHORE BLVD. NAPLES, FL 34102
338365844 0418800 2013-01-16 400 GULF SHORE BLVD., NAPLES, FL, 34102
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-01-17
Emphasis L: EISAOF, L: FALL, P: FALL
Case Closed 2013-05-09

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-04-18
Abatement Due Date 2013-04-30
Current Penalty 2754.0
Initial Penalty 4590.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On or about January 17, 2013, at the above addressed job site, employees worked on a mobile scaffold that was not inspected by a competent person.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260452 W02
Issuance Date 2013-04-18
Abatement Due Date 2013-04-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: a. On or about January 17, 2013, at the above addressed job site, employees were installing formwork from a mobile scaffold that had casters unlocked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-04-18
Abatement Due Date 2013-04-30
Current Penalty 3780.0
Initial Penalty 6300.0
Final Order 2013-05-09
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about January 16, 2013, at the above addressed job site, employees were exposed to a fall hazard while walking and working on top of a wall without using a means of conventional fall protection system.