Entity Name: | UNIVERSAL REILLY CONSTRUCTION, INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
UNIVERSAL REILLY CONSTRUCTION, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 14 May 2010 (15 years ago) |
Document Number: | P10000041872 |
FEI/EIN Number |
272620116
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 59 Nickajack North, Santa Rosa Beach, FL, 32459, US |
Mail Address: | 59 Nickajack North, Santa Rosa Beach, FL, 32459, US |
ZIP code: | 32459 |
County: | Walton |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
REILLY TIMOTHY P | President | 59 Nickajack North, Santa Rosa Beach, FL, 32459 |
REILLY TIMOTHY P | Agent | 59 Nickajack North, Santa Rosa Beach, FL, 32459 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G18000097646 | COASTAL BUILDERS FL | ACTIVE | 2018-09-02 | 2028-12-31 | - | 59 NICKAJACK N, SANTA ROSA BEACH, FL, 32459 |
G18000097644 | HIGH TIDE REALTY GROUP | ACTIVE | 2018-09-02 | 2028-12-31 | - | 59 NICKAJACK N, SANTA ROSA BEACH, FL, 32459 |
G10000068513 | UNIVERSAL CONSTRUCTION COMPANY | ACTIVE | 2010-07-26 | 2025-12-31 | - | 59 NICKAJACK N, SANTA ROSA BEACH, FL, 32459 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2020-01-24 | REILLY, TIMOTHY P | - |
CHANGE OF PRINCIPAL ADDRESS | 2016-03-21 | 59 Nickajack North, Santa Rosa Beach, FL 32459 | - |
CHANGE OF MAILING ADDRESS | 2016-03-21 | 59 Nickajack North, Santa Rosa Beach, FL 32459 | - |
REGISTERED AGENT ADDRESS CHANGED | 2016-03-21 | 59 Nickajack North, Santa Rosa Beach, FL 32459 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-02-06 |
ANNUAL REPORT | 2023-03-15 |
ANNUAL REPORT | 2022-04-01 |
ANNUAL REPORT | 2021-03-13 |
ANNUAL REPORT | 2020-01-24 |
ANNUAL REPORT | 2019-01-29 |
ANNUAL REPORT | 2018-03-19 |
ANNUAL REPORT | 2017-02-28 |
ANNUAL REPORT | 2016-03-21 |
ANNUAL REPORT | 2015-02-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339660227 | 0420600 | 2014-03-31 | 3301 S. KIRKMAN ROAD BLDG. #10, ORLANDO, FL, 32801 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 I |
Issuance Date | 2014-05-08 |
Current Penalty | 1600.0 |
Initial Penalty | 2520.0 |
Final Order | 2014-06-06 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) The supported scaffold erected at building #10 was not fully planked where spaces 18 inches wide were present on the second and third levels exposing the employees to a 15-foot fall hazard on or about April 1, 2014. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E06 I |
Issuance Date | 2014-05-08 |
Current Penalty | 1740.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-06-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(6)(i): Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs: (a). At building #10 the erected three stories high supporting scaffold's end frames which were not designed for ladder access, were being used for access and egress to the second and third scaffold levels on or about April 1, 2014 . |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2014-05-08 |
Current Penalty | 0.0 |
Initial Penalty | 1360.0 |
Final Order | 2014-06-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) At Building #10 of the Reserve Apartment Complex where exterior renovation was being done, the top cap and top step of the stepladder was used to gain access onto the scaffold, on or about April 1, 2014. |