Entity Name: | P & G CONTRACTORS, CORP |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
P & G CONTRACTORS, CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 10 Mar 2010 (15 years ago) |
Document Number: | P10000021479 |
FEI/EIN Number |
272092778
Federal Employer Identification (FEI) Number assigned by the IRS. |
Mail Address: | 541 NW 153 STREET, MIAMI, FL, 33169, US |
Address: | 541 NW 153 ST, MIAMI, FL, 33169, US |
ZIP code: | 33169 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
PALMA PERCY | President | 541 NW 153 STREET, MIAMI, FL, 33169 |
PALMA GLENDA | Vice President | 541 NW 153 STREET, MIAMI, FL, 33169 |
PALMA GLENDA | Agent | 541 NW 153 STREET, MIAMI, FL, 33169 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2014-04-28 | 541 NW 153 ST, MIAMI, FL 33169 | - |
CHANGE OF MAILING ADDRESS | 2014-04-28 | 541 NW 153 ST, MIAMI, FL 33169 | - |
REGISTERED AGENT ADDRESS CHANGED | 2014-04-28 | 541 NW 153 STREET, MIAMI, FL 33169 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-03-28 |
ANNUAL REPORT | 2023-04-05 |
ANNUAL REPORT | 2022-04-11 |
ANNUAL REPORT | 2021-03-17 |
ANNUAL REPORT | 2020-04-14 |
ANNUAL REPORT | 2019-06-17 |
ANNUAL REPORT | 2018-04-03 |
ANNUAL REPORT | 2017-04-20 |
ANNUAL REPORT | 2016-04-13 |
ANNUAL REPORT | 2015-04-27 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339074312 | 0418800 | 2013-05-17 | 8304 SUNSET DRIVE, MIAMI, FL, 33143 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-07-31 |
Abatement Due Date | 2013-08-12 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-09-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about May 17, 2013, at the above addressed jobsite, employees were exposed to a 10-foot fall hazard while doing roofing work. PLEASE NOTE: AN ABATEMENT CERTIFICATION IS REQUIRED WITH THIS VIOLATION. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B08 |
Issuance Date | 2013-07-31 |
Abatement Due Date | 2013-08-12 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-09-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: On or about May 17, 2013, at the above addressed jobsite, employees were exposed to a 10-foot fall while accessing a roof without a secured ladder. PLEASE NOTE: AN ABATEMENT CERTIFICATION IS REQUIRED WITH THIS VIOLATION. |
Date of last update: 03 Apr 2025
Sources: Florida Department of State